2-17
Setting Initial Operating Parameters
iControl AC
2
Table 2.2 Recommended iView Starting Values for Initial Operation
iView Screen Settings
Pattern >Common tab
Position Encoder
Resolution
348 if iLand-x-C Compact Landing system. 256 if iLand-x-H or LS-
EDGE. Otherwise, consult manufacturer documentation.
Job Contract Speed
200 fpm 350 fpm 400 fpm 500 fpm 600 + fpm Unit
Pattern scaling
100%
100%
100%
100%
100%
%
Door pre-opening dis.
0.00
0.00
0.00
0.00
0.00
inches
Leveling speed
005
005
005
005
005
fpm
Releveling speed
008
008
008
008
008
fpm
Leveling distance
1.20
0.72
0.60
0.60
0.60
inches
Releveling distance
0.60
0.60
0.60
0.60
0.60
inches
Dead zone distance
0.25
0.25
0.25
0.25
0.25
inches
Relevel dead zone dis.
0.15
0.15
0.15
0.15
0.15
inches
Pattern > Modes tab — Standard Profile
Job Contract Speed
200 fpm 350 fpm 400 fpm 500 fpm 600 + fpm Unit
Initial jerk
6.00
6.00
5.00
5.00
6.0
ft/s
3
Acceleration
2.40
3.20
3.40
3.60
3.80
ft/s
2
High toll jerk
6.00
6.00
5.00
5.00
4.00
ft/s
3
High speed
200
350
400
500
600
ft/min
Low roll jerk
6.00
6.00
5.00
5.00
4.00
ft/s
3
Deceleration
2.20
2.90
3.20
3.30
3.50
ft/s
2
Flare jerk
3.00
3.00
3.00
3.00
3.00
ft/s
3
Approach deceleration
1.50
1.50
1.50
1.50
1.50
ft/s
2
Approach jerk
2.00
2.00
2.00
2.00
2.00
ft/s
3
Pattern > Modes tab — Inspection Profile
Job Contract Speed
200 fpm 350 fpm 400 fpm 500 fpm 600 + fpm Unit
Initial jerk
6.00
6.00
5.00
5.00
6.0
ft/s
3
Acceleration
2.40
3.20
3.40
3.60
3.80
ft/s
2
High roll jerk
6.00
6.00
5.00
5.00
4.00
ft/s
3
High speed
30
30
30
30
30
ft/min
Low roll jerk
6.00
6.00
5.00
5.00
4.00
ft/s
3
Deceleration
2.20
2.90
3.20
3.30
3.50
ft/s
2
Flare jerk
3.00
3.00
3.00
3.00
3.00
ft/s
3
Approach deceleration
1.50
1.50
1.50
1.50
1.50
ft/s
2
Approach jerk
2.00
2.00
2.00
2.00
2.00
ft/s
3
Low speed
10
10
10
10
10
ft/min
General >General tab
Simplex car
Set to Simplex if the car is NOT in a group to enable dispatch and
parking screens (limited group functionality for a single car).
Summary of Contents for Nidec iControl
Page 1: ...MOTION CONTROL ENGINEERING User Guide iControl with AC Drive...
Page 15: ......
Page 23: ...1 8 Manual 42 02 2223 iControl Overview...
Page 75: ...2 52 Manual 42 02 2223 Construction Mode...
Page 89: ...3 14 Manual 42 02 2223 Inspection Mode...