6-31
iControl Messages
iControl AC
6
EEPROM Device Error, EEPROM DEVICE ERROR
Description: Safety Processor A EEPROM fault.
Car Reaction: Emergency stop: Motor contactor and brake contactor immediately dropped.
Troubleshooting:
1. Verify Safety Processor A EEPROM - board test. Contact MCE.
Elevator Recall Operation (Switch ‘n’), ELEVATOR RECALL SW’n’
(n = 1 to 6)
Description: Elevator Recall Operation has been initiated by the switch identified.
Car Reaction: In most usages, car immediately removes itself from hall call service, answers remaining car
calls, then proceeds to recall floor and cycles doors. (Disposition of car calls, recall floor, and door operation
user-programmable. iView/Car Operation/Elevator Recall.)
Emergency Alarm Acknowledged
Description: Indicates emergency alarm has been acknowledged and reset by Emergency Alarm Reset input.
Car Reaction: The Distress Light and the Distress Buzzer outputs will be extinguished.
Troubleshooting: NA
Emergency Alarm Activated (Alarm button), Emergency Alarm Activated, EMERG ALARM ACTI-
VATED
Description: Emergency Alarm input activated. Used to sound alarm and/or light indicator.
Car Reaction: Distress Light on until acknowledged by Emergency Alarm Reset input. Distress Buzzer pulsat-
ing or continuous as long as car remains in this condition.
Troubleshooting:
1. Attend to car and verify distress signal.
2. To reset alarm, verify alarm button is restored to normal condition, activate Emergency Alarm Reset.
Emergency Alarm Activated (Car delayed with doors closed)
Description: Indicates emergency alarm activated due to car being delayed with doors closed. This is an
optional emergency alarm monitor specified by user.
Car Reaction: Distress Light will be illuminated until acknowledged by Emergency Alarm Reset input. Distress
Buzzer output active as long as car remains in this condition.
Troubleshooting:
1. Attend to car and verify distress signal.
2. To reset alarm, verify car condition is restored to normal and activate the Emergency Alarm Reset.
Emergency Alarm Activated (In-car stop switch)
Description: Indicates emergency alarm activated due to in-car emergency stop switch pulled.
Car Reaction: Distress Light will be illuminated until acknowledged by Emergency Alarm Reset. Distress
Buzzer active as long as switch remains active.
Troubleshooting:
1. Attend to car and verify distress signal.
2. To reset, verify car emergency stop switch restored to normal position. Activate Emergency Alarm Reset.
Emergency Alarm Activated (Safety opened)
Description: Emergency alarm activated due to safety circuit open (excluding in-car emergency stop switch).
Optional emergency alarm monitor specified by the user.
Car Reaction: Distress Light on until acknowledged by Emergency Alarm Reset. Distress Buzzer active as
long as car remains in this condition.
Troubleshooting:
1. Attend to the car and verify the distress signal.
2. To reset, verify that car condition is restored to normal and activate the Emergency Alarm Reset input.
Emergency Alarm Deactivated without Acknowledgment
Description: Indicates emergency alarm deactivated because all signals that would activate it are now off
and Require Acknowledgment parameter is not checked.
Car Reaction: The Distress Light and Distress Buzzer outputs are deactivated.
Table 6.3 iControl Messages
iControl Messages
Summary of Contents for Nidec iControl
Page 1: ...MOTION CONTROL ENGINEERING User Guide iControl with AC Drive...
Page 15: ......
Page 23: ...1 8 Manual 42 02 2223 iControl Overview...
Page 75: ...2 52 Manual 42 02 2223 Construction Mode...
Page 89: ...3 14 Manual 42 02 2223 Inspection Mode...