9-38 Manual # 42-02-2223
Reference
DG Diagnostics Parameters (Combivis Only)
DG01 Input Status
None
I7
I8
I5
I6
I1
I2
I3
I4
0
1
2
4
8
16
32
64
128
0-255
DG02 Inverter Status See Section 6.16
0-255
DG03
Command
Speed
Geared
-4000- 4000
rpm
0
Gearless
-500.0-
500.0
0.0
DG04 Elevator
Position
-12000.0-
12000.0
in.
0.00
DG05 Actual Torque
Geared
-2214.0-
2214.0
lb-ft
0.0
Gearless
-22140-
22140
lb-ft
0
DG06 Motor Current
-3200.0-
3200.0
Amps
0.0
DG07 Motor Speed
Geared
-4000- 4000
rpm
0
Gearless
-500.0-
500.0
rpm
0.0
DG08 DC Bus Voltage
0-1000
Volts
0
DG09
Magnetizing
Current
-3200.0-
3200.0
A
0.0
DG10 Modulation
Grade
0-110
%
0
DG11 Output Status
None
O1
O2
RLY1
RLY2
0
1
2
4
8
0
0
DG16
Output
Condition
State
None
Condition 0
Condition 1
Condition 2
Condition 3
Condition 4
Condition 5
Condition 6
Condition 7
0
1
2
4
8
16
32
64
128
0
-
0
DG17
Output
Frequency
-
-
-400.0-
400.0
Hz
0.0
DG18 Output Voltage -
-
0-1000
Volts
0
DG19 Parameter Set -
-
0-7
-
0
Table 9.5 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para.
Name
Setting
Num
Range
Units
Default
Field