9-48 Manual # 42-02-2223
Reference
Speed Command 7 Multi-Step Speed command #7
ft/m
0
Speed Command 8 Multi-Step Speed command #8
ft/m
0
Speed Command 9 Multi-Step Speed command #9
ft/m
0
Speed Command 10 Multi-Step Speed command #10
ft/m
0
Speed Command 11 Multi-Step Speed command #11
ft/m
0
Speed Command 12 Multi-Step Speed command #12
ft/m
0
Speed Command 13 Multi-Step Speed command #13
ft/m
0
Speed Command 14 Multi-Step Speed command #14
ft/m
0
Speed Command 15 Multi-Step Speed command #15
ft/m
0
A4 Power Convert
Id Reg Diff gain
Flux Current regulator differential gain
-
0.80 - 1.20
1.00
Id Reg Prop Gain
Flux current regulator proportional gain
-
0.20 - 0.40
0.30
Iq Reg Diff Gain
Torque current regulator differential gain
-
0.80 - 1.20
1.00
Iq Reg Prop Gain
Torque current regulator proportional gain
-
0.20 - 0.40
0.30
PWM Frequency
Carrier frequency
kHz
2.5 - 16.0
10.0
UV Alarm Level
Level for undervoltage alarm
%
80 - 99
80
UV Fault Level
Level for undervoltage fault
%
50 - 88
80
Extern Reactance
External choke reactance
%
0 - 10
0
Input L-L Volts
Nominal line-line AC input Voltage, RMS
volts 110 - 480
Drive dep.
A5 Motor
Motor ID
Motor Identification
-
4 Pole DFLT, 6
Pole DFLT,
MCE Test
MCE Test
Rated Mtr Power
Rated motor output power
HP
1.0 - 500
5.0
Rated Mtr Volts
Rated motor terminal RMS voltage
volts 190.0 - 575.0 460
Rated Excit Freq
Rated excitation frequency
Hz
5.0 - 400.0
60
Rated Motor Curr
Rated motor current
amps 1.00 - 800.00 6.8
Motor Poles
Motor poles
-
2 - 32
6
Rated Mtr Speed
Rated motor speed at full load
RPM 50.0 - 3000.0 1130
% No Load Curr
Percent no load current
%
10.0 - 60.0
45
Stator Leakage X
Stator leakage reactance
%
0 - 20.0
9.0
Rotor Leakage X
Rotor leakage reactance
%
0 - 20.0
9.0
Stator Resist
Stator resistance
%
0 - 20.0
1.5
Motor Iron Loss
Iron loss at rated frequency
%
0 - 15.0
0.5
Motor Mech Loss
Mechanical loss at rated frequency
%
0 - 15.0
1.0
Ovld Start Level
Maximum continuous motor current
%
100 - 150
110
Ovld Time Out
Time that defines motor overload curve
sec
5.0 - 120.0
60.0
Flux Sat Break
Flux saturation curve slope change point
%
0 - 100
75
Flux Sat Slope 1
Flux saturation curve slope for low fluxes
%
0 - 200.0
0
Flux Sat Slope 2
Flux saturation curve slope for high fluxes
%
0 - 200.0
50
Table 9.7 Magnetek AC Drive Parameters Table
#
Operator
Display
Parameter Description
Unit
Setting
Range
MCE