7-7
LCD Display and Keypad
iControl AC
7
View Event Log
View Event log accesses the event database maintained by the controller. This database lists messages by
ID Number, ordered by time-of-occurrence. Additional data is also stored, e.g. Type, Date, Time, Acknowl-
edgement Status, and Event (name) for each event. A listing of iBox Event Log ID Numbers and a cross-ref-
erence to iControl Messages and descriptions can be found in Section 6 of this User Guide.
“Cross Reference: iBox Event Log ID Numbers to iControl Messages ” on page 6-4
and
To view the Event Log:
Press softkey (1) beneath the
Car
label, scroll down to
View Event Log
and press Enter. To view event
details, scroll to the desired event and press Enter.
Scroll down to see all data, including event name.
View/Register Calls
The View/Register Calls dialog allows you to send transport commands to the controller.
To View/Register Calls:
Allows you to enter car and hall calls for Front or Rear Car Operating Panels.
Set Time/Date
This parameter sets the real time clock for the controller.
To set the Set Time/Date:
Enter the current time and date for use by the controller real time clock.
View Factory Data
View Factory Data accesses serial number, date, and MAC address information for the controller. This infor-
mation is very useful should you ever have to contact MCE about your equipment.
MAC Addresses:
A six-byte, unique, identifying code used by LANs to positively identify communicating equipment. This
parameter allows you to view the MAC address for each of the three Ethernet ports.
Manufacturing Info:
View the controller serial number, revision, and ICE-IMP information.
Version Info
Version Info provides version information for the software currently installed on your controller.
Version Info:
View the software version information for the controller and car top processors.
View / Clear Statistics
View/clear statistical data collected by controller. Statistical data includes odometer, power-up cycles, front
and rear door cycles, motion cycles, floor time, floor runs, inspection runs, auto runs, and auto relevels.
Table 7.2 Mgmt Menu Parameters
Mgmt Menu Parameters
End Write Privilege
Use to cancel write privilege which has been granted to an iView PC connected to the controller.
Write Privilege Timeout
Use to change the write privilege timeout timer setting. The default value is 15 minutes.
Clone Controller Data
When
replacing an iBox
(or ICE-SAF board)
, this option allows safety learned and inventoried parameters
to be saved to flash memory. That memory can then be physically transferred to the new iBox
(or ICE-SAF
board)
, eliminating the need to enter or relearn those settings. Specific instructions for using this feature
are provided with the replacement iBox.
Table 7.1 Car Menu Parameters
Car Menu Parameters
Summary of Contents for Nidec iControl
Page 1: ...MOTION CONTROL ENGINEERING User Guide iControl with AC Drive...
Page 15: ......
Page 23: ...1 8 Manual 42 02 2223 iControl Overview...
Page 75: ...2 52 Manual 42 02 2223 Construction Mode...
Page 89: ...3 14 Manual 42 02 2223 Inspection Mode...