Magnetek HPV900 Series 2 Parameters Quick Ref-
iControl AC
9
Magnetek HPV900 Series 2 Parameters Quick Reference
This section includes quick reference information for the Magnetek HPV900 Series 2 AC Eleva-
tor drive parameters. Please refer to the Magnetek drive manual provided with iControl for a
detailed explanation. Enter the settings you make while adjusting into the Field Setting column.
Table 9.7 Magnetek AC Drive Parameters Table
#
Operator
Display
Parameter Description
Unit
Setting
Range
MCE
Defaults
Field
Setting
Adjust A0
A1 Drive
Contract Car Spd
Elevator Contract Speed
fpm
0 - 3000
0.1
Contract Mtr Spd
Motor Speed at elevator contract speed
rpm 50 - 3000
1130
Response
Speed regulator sensitivity. Set too high,
motor current and speed jittery. If too small,
motor will be sluggish.
rad/
sec
1.0 - 20.0
10
Inertia
System inertia
sec
0.25 - 50.00
2.0
Inner Loop Xover
Inner speed loop crossover frequency (only
with Ereg speed regulator)
rad/
sec
0.1 - 20.0
2.0
Gain Reduce Mult
Speed regulator response percentage to use in
low gain Mode. 100% = no reduction.
%
10 - 100
100
Gain Chng Level
Speed level to change to low gain mode
(only with internal gain switch)
%
0 - 100.0
100
Tach Rate Gain
Compensates for rope resonance. Use only
after A1, Inertia, and A1, Response, have
been set correctly.
%
0 - 30.0
0
Spd Phase Margin Phase margin of speed regulator
(only with PI speed regulator)
o
45 - 90
80
Ramped Stop Time Time to ramp from rated torque to zero (only
with torque ramp down stop function)
sec
0 - 2.50
0.20
Contact Flt Time
Time before a contactor fault is declared
sec
0.10 - 5.00
0.75
Brake Pick Time
Time before a brake pick fault is declared
sec
0 - 5.00
0.00
Brake Hold Time
Time before a brake hold fault is declared
sec
0 - 5.00
0.00
Overspeed Level
Threshold for detection of overspeed fault
%
100.0 - 150.0 125.0
Overspeed Time
Time before an overspeed fault is declared
sec
0 - 9.99
1.00
Overspeed Mult
Multiplier for overspeed test (U4)
%
100 - 150
100
Encoder Pulses
Encoder counts per revolution
ppr
600 - 10000
1024
Spd Dev Lo Level
Range around speed reference for speed devi-
ation low logic output
%
00.1 - 10.0
10
Spd Dev Time
Time before speed deviation low logic output
is true
sec
0 - 9.99
1.00
Spd DevHi Level
Level for declaring speed deviation alarm
%
0 - 99.9
20.0
Spd Command Bias Subtracts an effective voltage from actual
speed command voltage
volts 0 - 6.00
0.00
Spd Command Mult Scales analog speed command
-
0.90 - 3.00
1.00
Pre Torque Bias
Subtracts an effective voltage from actual pre
torque command voltage
volts 0 - 6.00
0.00
Pre Torque Mult
Scales pre-torque command
-
-10.00-10.00 1.00
Zero Speed Level
Threshold for zero speed logic output
%
0 - 99.99
1.00