P No.
Index P Name / Setting
Unit Function
732
MON_MotorPTC
Selection of sensor type
0
Type
Off (0)
No motor temperature sensor
KTY (1)
KTY84-130 Sensor
PTC (2)
PTC sensor (three) with short circuit monitoring
below 50 Ohm or hardware detection
TSS (3)
Switch (Klixon)
PTC1 (4)
PTC sensor (one) without short circuit
monitoring
PT100 (5)
PTC100 in line with DIN EN 60751
NTC220 (6)
NTC Sensor 220 kOhm
1)
NTC1000 (7)
NTC Sensor 1000 kOhm
NTC_K227 (8)
NTC Sensor K227 32 kOhm
KTY83-110 (9)
KTY83-110 Sensor
NTC50 (10)
NTC sensor 50 kOhm
NTC10 (11)
NTC Sensor 10 kOhm
PTC2 (12)
PTC sensor (simple) with short circuit
monitoring under 5 ohms
PT1000 (13)
PT1000 Sensor
1
Contact
Termination variant
X5(0)
Connection of the sensor to terminal X5
X6/7(1)
Sensor connection is routed in encoder cable
X5_X6/7(2)
Use of both inputs possible
X8(3)
X8 connector temperature sensor (tech opt
module)
X5_X8(4)
X5 and X8 connector temperature sensor (tech
opt module)
2
Type extended
Off (0)
No motor temperature sensor
KTY (1)
KTY84-130 Sensor
PTC (2)
PTC sensor (three) with short circuit monitoring
below 50 Ohm or hardware detection
TSS (3)
Switch (Klixon)
PTC1 (4)
PTC sensor (one) without short circuit
monitoring
Table 5.7: “Temperature monitoring” parameters (continued)
MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD Servo Drive - Device Help
40
5 Motor
P No.
Index P Name / Setting
Unit Function
PT100 (5)
PTC100 in line with DIN EN 60751
NTC220 (6)
NTC Sensor 220 kOhm
1)
NTC1000 (7)
NTC Sensor 1000 kOhm
NTC_K227 (8)
NTC Sensor K227 32 kOhm
KTY83-110 (9)
KTY83-110 Sensor
NTC50 (10)
NTC sensor 50 kOhm
NTC10 (11)
NTC Sensor 10 kOhm
PTC2 (12)
PTC sensor (simple) with short circuit
monitoring under 5 Ohm
PT1000 (13)
PT1000 Sensor
733
MON_MotorI2t
I
2
t characteristic setting
0
Inom
%
Rated current of the motor
1
I0
%
First current interpolation point of motor
protection characteristic: Maximum
permissible standstill current
2
I1
%
Second current interpolation point of motor
protection characteristic referred to maximum
characteristic current
3
F1
Hz
First frequency interpolation point of motor
protection characteristic
4
FNom
Hz
Rated frequency
5
IMax
%
Maximum overload current referred to rated
motor current
6
Time
s
Time for which the maximum current may be
connected
7
Ttherm
s
Set thermal time constant in seconds
735
0
MON_MotorI2tType
Motor protection mode
Off(-1)
Protection disabled
FREQU(0)
Motor frequency-dependent evaluation i(f),
default setting
THERM(1)
Evaluation with thermal time constant i
Tth
. The
thermal time constant is set with
P 733[7]
in
[s]. Due to measuring tolerances, the
shutdown threshold is 110 % of the rated value.
Table 5.7: “Temperature monitoring” parameters (continued)