NOTE
Additional times for the typical contact chatter on a contactor must
be taken into account when specifying the time for timer
P 148[0] -
MPRO_DRVCOM_ENMO_Time
. They may be several hundred
ms, depending on contactor.
MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD
Servo
Drive -
Device
Help
2
4
3
9 Input/Output settings
9.4 Analog inputs
Fig. 9.8: “Function selector of the analog inputs” dialog box
9.4.1 Standard analog inputs
There is a selector that can be used to assign a function to each analog
standard input (
P 109[0] - MPRO_INPUT_FS_ISA00
and
P 110[0] - MPRO_
INPUT_FS_ISA01
).
Certain functions will only be available with specific function packages.
Depending on the configured function, the “Options...” button may become
enabled. If it is, this button can be used to switch to a different screen directly
and define the function’s exact behaviour there.
Every analog input can be smoothed with a freely configurable filter time
(
P 405[0] - CON_ANA_Filt0
and
P 406[0] - CON_ANA_Filt1
).
P 427[0] - CON_ANA_CalibZero
can be used to trigger a zero correction
routine for both analog inputs. If you use this routine, there must not be any
voltage at the inputs.