ID
Index Name
Unit
Description
224
0
MPRO_REF_
TargetReachedOpC
Target reached option code
743
0
MON_UsrPosDiffMax
mDegree Position tracking error
2235
MPRO_402_
SoftwarePosLimit
607DH DS402 software position limit (SW
limit switch)
2235
0
MPRO_402_
SoftwarePosLimit
mDegree Minimum position limit (neg. SW limit switch)
2235
1
MPRO_402_
SoftwarePosLimit
mDegree Maximum position limit (pos. SW limit switch)
746
0
MON_UsrPosWindow
mDegree "Reference reached" window
Table 10.5: “Limits / thresholds - Position limits” parameters
NOTE
The response when a position limit is reached (
P 2235 - MPRO_
402_SoftwarePosLimit
) will depend on the error response that
has been configured (
MOOG
ID
No.:
CB40859-001
Date:
02/2018
MSD
Servo
Drive -
Device
Help
2
5
4
10 Limits / thresholds
10.5 Power Stage
If the DC link voltage value falls below the value set in
P 747[0] - MON_PF_
OnLimit
, error "ERR-34 Power failure detected" will be signalled and the
configured error response will be triggered (
" on
By configuring a quick stop (as an error response with a sufficiently steep
deceleration ramp), the DC link voltage can be maintained above the
undervoltage threshold (
"Power failure bridging" on page
This reaction lasts until the drive has been braked to a lower speed.
ID
Index Name
Unit Description
747
0
MON_PF_ONLimit
V
Voltage limit for power failure
749
0
MON_DevOverVoltage
V
Overvoltage DC-link
750
MON_CurrToGround
Fault current
750
0
Current to ground
A
Maximum fault current to ground
750
1
Current in power-off
A
Maximum fault current in power-off
757
0
MON_PwrActVal_Tf
ms
Filter time constant for actual power values
Table 10.6: “Limits / thresholds - Power stage” parameters