54
MSD Multi-Axis System Operation Manual DC-AC Servo Drive
5.2.2
Connection between PC and DC-AC Servo Drive
3.
The PC can be connected to the DC-AC Servo Drive via USB or Ethernet (TCP/IP). Connect PC and
DC-AC Servo Drive using the related connection cable.
NOTE:
• I
nitialisation
The communication link between PC and DC-AC Servo Drive can only be
set up after the servo drive has completed its initialisation.
• U
SB driver and TCP/IP configuratio
n
If the PC does not recognise the DC-AC Servo Drive connected, please
check the driver and the settings for the related interface (see Installation
Manual Moog
D
rive
A
DministrAtor
5).
5.2.3
Configuring parameter
4.
The commissioning wizard in Moog
D
rive
A
DministrAtor
5 is provided for making the settings for the
drive system. Start the wizard.
NOTE:
•
Online help
You will find a detailed description of Moog
D
rive
A
DministrAtor
5 and the
commissioning wizard in the online help for Moog
D
rive
A
DministrAtor
5.
•
Motor data set
On using Moog Synchronous Motors of type the latest
version of the motor data set required can be obtained from
http://www.
moogsoftwaredownload.com/msd.html “Motor
Configuration files
".
5.2.1
Switching on control supply
2.
To initialise and configure parameters, initially only switch on the +24 V control supply. Do
not
yet
switch on the power supply.
Display indication after switching on the control supply
D1
D2
Action
Explanation
Switching on the ext. +24 V control supply
Initialisation in progress
Initialisation completed
Not ready to switch on
Table 5.1 Switch-on status of the DC-AC Servo Drive on connection of the +24 V DC control
supply
NOTE:
You will find details on the control supply in
You will find details on the display indication in
moog
Id. no.: CA97554-001 0
5
/2017
5 Commissioning