MSD Multi-Axis System Operation Manual DC-AC Servo Drive
moog
Id. no.: CA97554-001 0
5
/2017
51
4 Electrical installation
Technical data
Technical data
C08336-xxx-yyy
1),2)
CB05708-xxx-yyy
1),2)
CA44958-xxx-yyy
1),2)
CB00076-xxx-yyy
1),2)
CA98676-xxx-yyy
1),2)
Continuous rated
current
10 A
TBD
44 A
61 A
82 A
Cable cross-section
4 x 1,5 mm² + 2 x 1 mm²
(4 x 0.0024 in² + 2 x 0.0016 in²)
4 x 4 mm² + 2 x 1,5 mm²
(4 x 0.0062 in² + 2 x 0.0023 in²)
4 x 6 mm² + 2 x 1,5 mm²
(4 x 0.0093 in² + 2 x 0.0023 in²)
4 x 10 mm² + 2 x 1,5 mm²
(4 x 0.00155 in² + 2 x 0.0023 in²)
4 x 16 mm² + 2 x 1,5 mm²
(4 x 0.0248 in² + 2 x 0.0023 in²)
Temperature range
-40 bis +125 °C
(-40 to +275 °F)
TBD
-50 bis +90 °C
(-58 to +194 °F)
TBD
TBD
Wiring
Connector pin
Wiring
Connector pin
Wiring
Connector pin
Wiring
Connector pin
Wiring
Connector pin
Wiring
2
U
2
U
U
U
U
U
U
U
4
VV
4
VV
V
VV
V
VV
V
VV
1
WWW
1
WWW
W
WWW
W
WWW
W
WWW
PE
yellow / green
PE
yellow / green
PE
yellow / green
PE
yellow / green
PE
yellow / green
5
Brake + / white
5
Brake + / white
+
Brake - / white
+
Brake + / white
+
Brake + / white
6
Brake - / black
6
Brake - / black
-
Brake - / black
-
Brake - / black
-
Brake - / black
Connector
housing
Monitor
Connector
housing
Monitor
Connector
housing
Monitor
Connector
housing
Monitor
Connector
housing
Monitor
Connector type
Size 1
Size 1
Size 1
Size 1
Size 1
1) yyy stands for length in meters; standard length: 1 m (3.28 ft), 5 m (16.40 ft), 10 m (32.80 ft), 15 m (49 ft), 20 m (65 ft), 50 m (164 ft). Further length on request
2) xxx-001 for standard configuration option, further options on equest
Table 4.15 Technical data motor cab
NOTE:
Cores 5 and 6 (PTC) are required only for motors in which the motor PTC
cannot be connected via the encoder cable. In the case of servomotors with