MSD Multi-Axis System Operation Manual DC-AC Servo Drive
99
A Technical data
A.4 Current required for the control supply
Size
Size 1
Size 2
Size 3
Size 4
Size 5
Size 6A
Device
G393-004
G393-006
G393-008
G393-012
G393-016
G393-020
G393-024
G393-032
G393-045
G393-060
G393-072
G393-090
G393-110
G393-143
G393-170
Air cooling
Maximum starting
current
6 A
7 A
10 A
Rated current
2 A
2.5 A
8 A
Table A.19 Current required for the control supply
Size
Size 3
Size 4
Size 5
Size 6A
Size 7
Device
G397-020
G397-025
G397-026
G397-035
G397-053
G397-070
G397-084
G397-110
G397-143
G397-170
G397-210
G397-250
G397-325
G397-450
Liquid cooling
Maximum starting
current
6 A
7 A
8 A
5 A
Rated current
2 A
2 A
2 A
4 A
Table A.20 Current required for the control supply
Size
Size 7
Device
G397-250
G397-325
G397-450
X11/ZK+, ZK-
Screw size for ring cable lug
M12
Tightening torque
25 to 30 Nm (221 to 265 lb-in)
X11/PE
1)
Screw size for ring cable lug
M10
Tightening torque
20 to 25 Nm (177 to 221 lb-in)
X12/L1, L2, L3
Screw size for ring cable lug
M12
Tightening torque
25 to 30 Nm (221 to 265 lb-in)
X12/PE
1)
Screw size for ring cable lug
M12
Tightening torque
25 to 30 Nm (221 to 265 lb-in)
X12/RB+, RB-
Screw size for ring cable lug
M10
Tightening torque
20 to 25 Nm (177 to 221 lb-in)
1)
The protective earth conductor cross-section depends on the cross-section of the phase conductor. See chapter 4.4,
page 36.
The minimum cross-section of the connection cables depends on the local regulations, conditions as well as on the rated
current of the Power Supply Unit.
Table A.18 Busbar connections
moog
Id. no.: CA97554-001 0
5
/2017