60
MSD Multi-Axis System Operation Manual DC-AC Servo Drive
NOTE:
•
During the flashing phase after step 7 the
save procedure can still be
aborted by pressing any button, without applying the value set. Otherwise
the new value will be saved after five seconds
• T
he modified IP add
ess is only effective after restarting the control
electronics (24-V reset).
5.4.5
Field bus address menu (Fb)
The functions available on this menu item depend on the device's communication
option. For detailed information refer to the relevant specification
Menu level
Pa-
rame-
ter
Value
range
Meaning
Explanation
1
2
Fb
Ad
-
00..xx
or
- -
Field bus address
Setting for field bus address
(only if field bus option used), otherwise indication
"- -"
(The maximum value that can be programmed
depends on the option)
Po
-
0..3
or
- -
Transmit power
Setting for fibre-optic power output
(only with SERCOS II option),
otherwise indication "- -"
Table 5.10 Field bus address menu
Example configuration of the subnet mask
In this example the subnet mask is changed from 255.255.255.0 to 122.255.255.0.
T1
T2
Tx
Tx
back
back
back
several actuations
of buttonTx (X = 1, 2)
until the desired menu
appears in the display
single actuation
of button Tx (X = 1, 2)
simultaneous actuation
of both buttons T1 and T2
Actuation of
any button
accept
>5 s
>5 s
<5 s
T2
<5 s
T1 T2
T1 T2
T1 T2
back
T1 T2
back
T1 T2
T1 T2
T1 T2
T1 T2
Value NOT
saved
Value
saved
T1
T2
T1
T1
back
T1 T2
T2
Figure 5.2 Example configuration of the subnet mask