MSD Multi-Axis System Operation Manual DC-AC Servo Drive
43
4 Electrical installation
Des.
Term.
Specification
Electrical isolation
Relay outputs
REL
X4/23
X4/24
Relay, 1 NO contact
• 25 V / 1.0 A AC, cos
ϕ
= 1
• 30 V / 1.0 A DC, cos
ϕ
= 1
• Switching delay approx. 10 ms
• Cycle time 1 ms
X4/23
X4/24
Yes
Auxiliary voltage
+24 V
X4/2
X4/14
• Auxiliary voltage for supplying the digital control inputs
• U
H
= U
V
-∆U (∆U typically approx. 1.2 V), no irreparable
damage in event of short circuit (+24 V -> GND), but
device may briefly shut down.
• I
MAX
= 80 mA (per pin) with self-resetting circuit breaker
(polyswitch)
Yes
Digital ground
DGND
X4/1
X4/13
Reference ground for +24 V, I
MAX
= 80 mA (per pin), hardware
versions 0..1 with self-resetting circuit breaker (polyswitch)
Yes
Table 4.6 Specification of the control connections X4
NOTE
High-impedance isolation in the relation to device ground
If excessively high currents flow via the earth terminals, high-impedance
isolation from the device ground is possible. In some circumstances this can
result in the malfunction of the drive. To prevent this situation arising, avoid
currents circulating in the wiring.
NOTE:
Take into account that in the event of a fault, the Power Supply Unit may no
longer be able to feed regenerative energy from the DC-AC Servo Drive to
the mains. To prevent irreparable damage to the Power Supply Unit's braking
resistor on extended regenerative operation, the DC-AC Servo Drives and the
Power Supply Unit can be mutually interlocked via terminal X4. You will find
further information and an example circuit in
Des.
Term.
Specification
Electrical isolation
ENPO
X4/10
• Disable the restart inhibit (STO) and enable the power
stage = high level
• OSSD support (from hardware version 2)
• Response time approx. 10 ms
• Switching level low/high: ≤4.8 V / ≥18 V
• U
IN max
= +24 V DC +20 %
• I
IN
at +24 V DC = typ. 3 mA
Yes
REL
REL
ISDSH
ISD06
ISD05
ISD04
ISD03
ISD02
ISD01
ISD00
+24V
DGND
RSH
RSH
ENPO
OSD02
OSD01
OSD00
ISA1-
ISA1+
ISA0-
ISA0+
+24V
DGND
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
X4
Digital outputs
OSD00
OSD01
OSD02
X4/7
X4/8
X4/9
• No irreparable damage in the event of a short circuit
(+24 V -> GND), however, device may briefly shut down
• I
MAX
= 50 mA, PLC-compatible
• Terminal scan cycle in = 1 ms
• High-side driver
Yes
STO ("Safe Torque Off") *)
ISDSH
(STO)
X4/22
• Input "Request STO" = low level
• OSSD support (from hardware version 2)
• Switching level low/high: ≤4.8 V / ≥18 V
• U
IN max
= +24 V DC +20 %
• I
IN
at +24 V DC = typ. 3 mA
Yes
RSH
RSH
X4/11
X4/12
Diagnostics STO, both shut-off channels
active, one NO contact with automatically
resetting circuit breaker (polyswitch)
• 25 V / 200 mA AC, cos
ϕ
= 1
• 30 V / 200 mA DC, cos
ϕ
= 1
X4/12
X4/11
Yes
*) STO certification applies for DC-AC Servo Drives of size Size 1 to Size
7
Table 4.6 Specification of the control connections X4
moog
Id. no.: CA97554-001 0
5