MSD Multi-Axis System Operation Manual DC-AC Servo Drive
39
4 Electrical installation
4.6.2
G397-250
to G397-450 (Size 7)
Terminal/pin
Specification
X44/1 = +
X44/2 = -
• U
V
= +24 V DC -20 % +10 %, stabilised and smoothed
• For max. starting and continuous currents see chap. A.4
• Fuse protection for the terminal max. 10 A
• Internal polarity reversal protection
• The Power Supply Unit used must have safe and reliable isolation in relation to the mains
as per EN 50178 or IEC/EN 61800-5-1.
Table 4.5 Specification, control supply Size 7
4.6.1
G393-004 (Size 1) to G393-170/G397-210 (Size 6A)
DC power supply
DC power supply
+24 V DC ± 20 %
external voltage
supply
D1 D2
next servo drive
maximum
10 A gG
Looping only possible
for Size 1 to Size 4
1
2
1
2
D1 D2
1
2
1
2
+
-
+
-
+
-
+
-
Top side
Top side
Device 1
Device 2
X9
X10
X11
X9
X10
DC -
DC +
X11
DC -
DC +
Figure 4.14 Connection for control supply
Terminal/pin
Specification
X9/1 = +
X9/2 = -
• U
V
= +24 V DC -20 % +10 %, stabilised and smoothed
• For maximum starting and continuous currents see chap. A.4
• Fuse protection for the terminal maximum 10 A
• Internal polarity reversal protection
• The Power Supply Unit used must have safe and reliable isolation in relation to the mains
as per EN 50178 or IEC/EN 61800-5-1.
• Connected internally to X10
X10/1 = +
X10/2 = -
• Connected internally to X9
Table 4.4 Specification, control supply Size 1 to Size 6A
moog
Id. no.: CA97554-001 0
5
/2017