90
MSD Multi-Axis System Operation Manual DC-AC Servo Drive
A.1.4
G393-004 to G393-032 (
air cooling, 770 V DC)
Device
Switching
frequenc
y of the
power stage
Ambient
temperature
Rated current
Peak current
1)
I
MAX
0 Hz
I
1MAX
≥5 Hz
t
1
2)
I
2MAX
≥5 Hz
t
2
2)
[kHz]
[°C (°F)]
[A
eff
]
[A
eff
]
[A
eff
]
[s]
[A
eff
]
[s]
G393-004 (Size 1)
4
+40
(+104)
5.1
8.1
8.1
10
11.5
0.5
8
3.2
6.8
6.8
-
-
12
2.1
3.8
3.8
-
-
16
1.1
2.1
2.1
-
-
G393-006 (Size 1)
4
+40
(+104)
7.6
12.1
12.1
10
17.1
0.5
8
4.8
10.2
10.2
-
-
12
3.2
5.7
5.7
-
-
16
1.6
3.1
3.1
-
-
G393-008 (Size 2)
4
+40
(+104)
8.0
13.7
13.7
10
20.6
0.5
8
5.9
10.1
10.1
-
-
12
5.3
7.4
7.4
-
-
16
3.7
5.2
5.2
-
-
G393-012 (Size 2)
4
+40
(+104)
11.2
19.2
19.2
10
28.8
0.5
8
8.8
15.1
15.1
-
-
12
7.9
11.1
11.1
-
-
16
5.5
7.7
7.7
-
-
1) At maximum 70 % pre-load
2) Shutdown as per I²t characteristic
All data apply for a motor cable length ≤10 m (32.80 ft)
Table A.4 Rated and peak current, G393-004 to G393-032 (air cooling, 770 V DC)
Device
Switching
frequenc
y of the
power stage
Ambient
temperature
Rated current
Peak current
1)
I
MAX
0 Hz
I
1MAX
≥5 Hz
t
1
2)
I
2MAX
≥5 Hz
t
2
2)
[kHz]
[°C (°F)]
[A
eff
]
[A
eff
]
[A
eff
]
[s]
[A
eff
]
[s]
G393-016 (Size 3)
4
+40
(+104)
20.0
33.6
33.6
10
48.0
0.5
8
13.3
27.9
27.9
-
-
12
8.5
18.3
18.3
-
-
16
6.0
13.7
13.7
-
-
G393-020 (Size 3)
4
+40
(+104)
25.0
42.0
42.0
10
60.0
0.5
8
16.6
34.8
34.8
-
-
12
10.0
21.5
21.5
-
-
16
6.5
14.8
14.8
-
-
G393-024 (Size 4)
4
+40
(+104)
26.0
41.6
41.6
10
62.4
0.5
8
20.0
40.0
40.0
-
-
12
11.3
22.6
22.6
-
-
16
8.4
16.8
16.8
-
-
G393-032 (Size 4)
4
+40
(+104)
32.5
52.0
52.0
10
78.0
0.5
8
26.7
53.4
53.4
-
-
12
15.0
30.0
30.0
-
-
16
11.2
22.4
22.4
-
-
1) At maximum 70 % pre-load
2) Shutdown as per I²t characteristic
All data apply for a motor cable length ≤10 m (32.80 ft)
Table A.3 Rated and peak current, G393-004 to G393-032 (air cooling, 480 V AC)