Figure 3.13 Dimensional drawing, liquid cooling housing variant, based on Size 5 as an example
H1 C
A
A
T
B
T1
H
A1
A2
H3
S
D1
D
Figure 3.14 Dimensional drawing, liquid cooling housing variant, based on Size 7 as an example
Size
Size 3
Size 4
Size 5
Size 6A
Size 7
Device
G397-020
G397-025
G397-026
G397-035
G397-053
G397-070
G397-084
G397-110
G397-130
G397-170
G397-210
G397-250
G397-325
G397-450
S [inch]
3/8 (female thread)
Screws
4 x M4
4 x M6
4 x M8
6 x M10
T1
73.5 (2.89)
All dimensions in mm (in)
1) Without terminals/connections
2) Also pay attention to the bending radius of the connection cables
Table 3.2 Dimensions and mounting clearances, liquid cooling housing variant
NOTE:
The minimum distance specified in the table applies for devices of the same
power. On side by side mounting devices with different drive powers you
should arrange the devices in descending order by power rating (e.g., viewed
from the left, Size 4-Size 3-Size 2-Size 1). This arrangement will minimise the
thermal interaction. The Power Supply Unit must always be fitted beside the
DC-AC Servo Drive with the highest power.
On side by side mounting other devices to the multi-axis system, attention is
to be paid to ensuring there is no thermal interaction between the devices.