M-Style Motors: RS-232 to RS-485 Multidrop
M-Style Motors: RS-232 to RS-485 Multidrop
CBLIP-COM-FL (8 Pin)
CBLIP-COM-Y1-xM
4 3 2 1
RS232485T
NOTE:
RS-485 serial communications uses a voltage differential signal that requires proper
termination with a 120 ohm resistor across pins 2 and 3 at both ends of the network cable. This
follows RS-485 standards for biasing to ensure reliable performance. The termination can be
created by adding the resistor to CBLIP-COM-FL Flying Lead cables or to off-the-shelf connectors.
This communications-connection method would be combined with a power-connection method. For
example, see M-Style Motors: Power, RS-485 Com and CAN Multidrop on page 47.
Moog Animatics Class 5 SmartMotor™
Installation and Startup Guide,
Rev. I
Page 48 of 76