7. COMPUTER LINK CONNECTION
7.5 PLC Side Setting
7 - 19
7
COMPUTER LINK
C
O
NN
ECTION
7.5
PLC Side Setting
The GOT operates under the following transmission
specifications when it is connected to a Mitsubishi PLC in
the computer link connection.
The PLC side settings (the serial communication module,
computer link module) are explained in Section 7.5.1 to
Section 7.5.3.
7.5.1
Connecting serial
communication module (Q, L
Series)
POINT
POINT
POINT
(1) Serial communication module (Q, L Series)
For details of the serial communication module (Q,
L Series), refer to the following manual.
Q Corresponding Serial Communication
Module User’s Manual (Basic)
MELSEC-L Serial Communication Module
User's Manual (Basic)
(2) Modem interface module
For details of the modem interface module, refer to
the following manual.
Modem Interface Module User's Manual
[Intelligent function module switch setting] on
GX Developer
[The intelligent function module switch setting] on GX
Developer is not necessary. (When no [intelligent
function module switch setting] is made, the module
runs in the GX Developer connection mode.)
A module can be also connected to a GOT by making
the following [intelligent function module switch setting]
on GX Developer.
(1) When connecting to the CH1 side
Transmission specifications
Setting
Data bit
8bits
Parity bit
Yes (Odd)
Stop bit
1bit
Sum check
Yes
Transmission speed
(Baud rate)
Set the same transmission speed on
both the GOT and the PLC.
Model
Refer
to
Serial communication module
(Q Series)
QJ71C24N,
QJ71C24
QJ71C24N-R2,
QJ71C24-R2
QJ71C24N-R4
Modem interface module
QJ71CMO,
QJ71CMON
Serial communication module
(L Series)
LJ71C24,
LJ71C24-R2
Serial communication module
(QnA Series)
AJ71QC24N,
AJ71QC24
AJ71QC24N-R2,
AJ71QC24-R2
AJ71QC24N-R4,
AJ71QC24-R4
A1SJ71QC24N1,
A1SJ71QC24N,
A1SJ71QC24
A1SJ71QC24N1-R2,
A1SJ71QC24N-R2,
A1SJ71QC24-R2
Computer link module
AJ71UC24
A1SJ71UC24-R2,
A1SJ71UC24-PRF,
A1SJ71C24-R2,
A1SJ71C24-PRF
A1SJ71UC24-R4,
A1SJ71C24-R4
A1SCPUC24-R2
A2CCPUC24,
A2CCPUC24-PRF
Switch
No.
Bit
Description
Set
value
*3
Positi
on
Specifi
ed
value
Switch 1
b0
OFF
CH1
transmiss
ion
settings
*1
Operation
setting
(Operates
according
to the GOT
side
specificatio
ns.)
0000
H
b1
OFF
Data Bit
b2
OFF
Parity Bit
b3
OFF
Even/Odd
parity
b4
OFF
Stop bit
b5
OFF
Sum
check
code
b6
OFF
Write
during
RUN
b7
OFF
Setting
modifica-
tions
b8 to
b15
―
CH1 transmission
speed setting
*2
Switch 2
―
CH1 Communication
protocol setting
GX
Developer
connection
0000
H
Switch 5
―
Station number setting 0th station
0000
H
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......