2 - 12
2. DEVICE RANGE THAT CAN BE SET
2.5 MELSEC-FX
2.5
MELSEC-FX
The device ranges that can be set when selecting
[MELSEC-FX] as the controller type are as follows.
*1
When executing the touch switch function set during the bit
specification of the word device, do not write any data to the
word device through the sequence program.
*2
The device No. must be set in multiples of 16.
*3
Only 16-bit (1-word) designation is allowed.
*4
For CS0 to CS199, only 16-bit (1-word) designation is
allowed.
For CS200 to CS255, only 32-bit (2-word) designation is
allowed.
*5
Monitoring or writing is not possible in the continuous device
designation mode.
In addition, setting values of the timer and counter, which are
not used for the program, cannot be monitored. If monitoring
is executed, a reading error occurs.
*6
Can be used only for special blocks or special units
compatible with FX
1N
, FX
1NC
, FX
2N
, FX
2NC
, FX
3G
, FX
3GC
,
FX
3U
, FX
3UC
.
(Except FX
0N
-3A, FX
2N
-2AD, and FX
2N
-2DA)
POINT
POINT
POINT
(1) Precautions when using the buffer memory
• When the power supply of the special block or
special module is turned off, the contents of the
buffer memory are initialized, except for some
keeping areas.
• When the buffer memory is monitored by the
GOT, the PLC scan time may increase instantly.
• Use the 16 bit specification for the buffer
memory of 16 bit data. Use the 32 bit
specification for the buffer memory of 32 bit data.
If using the 16 bit specification for a buffer
memory of 32 bit data, monitoring and writing
may not be executed normally.
For the data size of each buffer memory, refer to
the following.
User's Manual of the special block or special
module
• When reading from/writing to the special block or
special module by interrupt processing of the
sequence program, monitoring/writing from GOT
to the buffer memory may not be executed
normally.
(2) How to select a keyword protection level
For equipment that are allowed to operate the FX
PLC online, 3 levels of protection level can be set.
When monitoring or changing settings by any
online equipment is required, set a keyword
referring to the following.
(a) When setting the keyword only
Select a protection level by the initial letter of
the keyword.
All operation protect: Set a keyword with the
initial letter "A", "D" to "F", or "0" to "9".
Incorrect write/read protect: Set a keyword
with the initial letter "B".
Incorrect write protect: Set a keyword with the
initial letter "C".
(b) When setting the keyword and 2nd keyword
Select a protection level by [Registration
condition].
(3) Monitoring availability at each keyword protection
level
The following shows the device monitoring
availability at each keyword protection level.
*1
When the T, C set values are specified indirectly, changing
devices is available.
(4) Difference between all online operations
prohibition and all operations prohibition
When specifying all online operations prohibition,
displaying devices and inputting data with
programming tools or GOT are all prohibited.
When all operations are prohibited, displaying
devices and inputting data with the GOT are
enabled while all operations using programming
tools are prohibited.
Device name
Setting range
Device No.
representation
Bi
t d
e
v
ice
Input relay (X)
X0
to
X377
Octal
Output relay (Y)
Y0
to
Y377
Auxiliary relay (M)
M0
to
M7679
Decimal
Special auxiliary relay (M)
M8000 to
M8511
State (S)
S0
to
S4095
Timer contact (T)
T0
to
T511
Counter contact (C)
C0
to
C255
Word device bit
*1
Specified bit of the
following word devices
(Except Timer (set value)
and Counter (set value))
―
W
o
rd device
Data register (D)
D0
to
D0999
Decimal
File register (D)
D1000 to
D7999
Special data register (D)
D8000 to
D8511
Timer (current value) (T)
T0
to
T511
Counter (current value)
(C)
C0
to
C255
Timer (set value) (TS)
*3*5
TS0
to
TS511
Counter (set value)
(CS)
*4*5
CS0
to
CS255
Extension register (R)
R0
to
R32767
Index register (V)
V0
to
V7
Index register (Z)
Z0
to
Z7
Buffer memory (BM)
*6
BM0
to
BM32767
Bit device word
*2
Converting the above bit
devices into words
(Except Timer contact
and Counter contact)
Item
When registering the
keyword only
When registering the
keyword and 2nd
keyword
Keyword
not
registered
or
protection
cancelled
All
operation
protect
Incorrect
write/
read
protect
Incorrect
write
protect
All online
operation
protect
Read/
write
protect
Write
protect
Monitoring
devices
Changing
devices
T, C set
value
and file
register
(D1000
and the
following)
*1
*1
*1
Other
than
above
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......