8 - 28
8. BUS CONNECTION
8.2 System Configuration
When two GOTs are connected
*1
For the extension cables, refer to MELSEC-A/QnA catalog (L(NA)08024).
*2
Use the A168B for the extension base unit.
*3
When installing the 1st GOT 30m or more away from the main base unit, the bus connector conversion box is required.
*4
When connecting to multiple GOTs with GT27, GT 16, GT15 and GT11 mixed, use GT11 as a terminal.
*5
When using GT15-C
EXSS-1 or GT15-C
BS, connect as following precautions.
8.4.1 GT15-C [ ] EXSS-1, GT15-C [ ] BS
*6
The number of connectable GOTs is restricted according to the CPU type and the number of intelligent function modules.
8.4.12 When connecting multiple GOTs
Main base unit
Bus extension
connector box
Extension base
unit
Connection cable 1)
Connection cable 2)
Connection cable 3)
Extension cable
1st GOT
2nd GOT
Communication driver
Bus(A/QnA)
PLC
*5
Connection cable 2)
GOT (1st)
*4
Main base
Extension
cable
*1
Extension
base
*2
Connection cable 1)
Bus connector
conversion box
Option device
*7*8
Model
Main base
-
-
-
-
GT15-A1SC07B(0.7m)
GT15-A1SC12B(1.2m)
GT15-A1SC30B(3m)
GT15-75ABUS2L
GT15-ABUS2
-
-
GT15-C100EXSS-1(10m)
GT15-C200EXSS-1(20m)
*5
GT15-75ABUS2L
GT15-ABUS2
GT15-A1SC05NB(0.45m)
GT15-A1SC07NB(0.7m)
GT15-A1SC30NB(3m)
A7GT-CNB
*3
GT15-C100EXSS-1(10m)
GT15-C200EXSS-1(20m)
*5
GT15-75ABUS2L
GT15-ABUS2
Main base
Extension
cable
Extension
base
-
-
GT15-A1SC07B(0.7m)
GT15-A1SC12B(1.2m)
GT15-A1SC30B(3m)
GT15-75ABUS2L
GT15-ABUS2
-
-
GT15-C100EXSS-1(10m)
GT15-C200EXSS-1(20m)
*5
GT15-75ABUS2L
GT15-ABUS2
GT15-A1SC05NB(0.45m)
GT15-A1SC07NB(0.7m)
GT15-A1SC30NB(3m)
A7GT-CNB
*3
GT15-C100EXSS-1(10m)
GT15-C200EXSS-1(20m)
*5
GT15-75ABUS2L
GT15-ABUS2
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......