15 - 30
15. SERVO AMPLIFIER CONNECTION
15.6 Device Range that Can Be Set
*1
For the parameters prefixed by an asterisk (*), setting
becomes effective when the power is turned off once and
back on after setting the parameter data.
(e) Status display
(f)
Alarm
PRM48, PRM1048
Software limit-
*LMN
PRM49, PRM1049
PRM50, PRM1050
Position range output
*LPP
PRM51, PRM1051
PRM52, PRM1052
Position range output address-
*LNP
PRM53, PRM1053
PRM54, PRM1054
For manufacturer setting
―
PRM55, PRM1055
Function selection 6
*OP6
PRM56, PRM1056
For manufacturer setting
―
PRM57, PRM1057
Function selection 8
*OP8
PRM58, PRM1058
Function selection 9
*OP9
PRM59, PRM1059
Function selection A
*OPA
PRM60, PRM1060
For manufacturer setting
―
PRM61, PRM1061
Machine resonance
suppression filter 1
NH1
PRM62, PRM1062
Machine resonance
suppression filter 2
NH2
PRM63, PRM1063
Low-pass filter,
adaptive vibration suppression
control
LPF
PRM64, PRM1064
Ratio of load inertia moment
to Servo motor inertia moment 2
GD2B
PRM65, PRM1065
Position control gain 2
changing ratio
PG2B
PRM66, PRM1066
Speed control gain 2 changing
ratio
VG2B
PRM67, PRM1067
Speed integral compensation
changing ratio
VICB
PRM68, PRM1068
Gain changing selection
*CDP
PRM69, PRM1069
Gain changing condition
CDS
PRM70, PRM1070
Gain changing time constant
CDT
PRM71 to PRM73,
PRM1071 to PRM1073
For manufacturer setting
―
PRM74, PRM1074
OUT1 output time selection
OUT1
PRM75, PRM1075
OUT2 output time selection
OUT2
PRM76, PRM1076
OUT3 output time selection
OUT3
PRM77, PRM1077
Selected to program input
polarity selection 1
SYC1
PRM78 to PRM90,
PRM1078 to PRM1090
For manufacturer setting
―
Device name
Item
Symbol
ST0
Current position
―
ST1
Command position
―
ST2
Command remaining distance
―
ST3
Program Number
―
ST4
Step Number
―
ST5
Cumulative feedback pulses
―
ST6
Servo motor speed
―
ST7
Droop pulses
―
ST8
Override
―
ST9
Torque limit voltage
―
ST10
Regenerative load ratio
―
ST11
Effective load ratio
―
ST12
Peak load ratio
―
ST13
Instantaneous torque
―
ST14
Within one-revolution position
―
ST15
ABS counter
―
ST16
Load inertia moment ratio
―
ST17
Bus voltage
―
Device name
Item
Symbol
*1
Device
name
Item
Symbol
AL0
Current alarm number
―
AL1
Detailed data of current alarms
―
AL11
Servo status when alarm occurs Current
position
―
AL12
Servo status when alarm occurs Command
position
―
AL13
Servo status when alarm occurs Command
remaining distance
―
AL14
Servo status when alarm occurs Program
Number
―
AL15
Servo status when alarm occurs Step Number
―
AL16
Servo status when alarm occurs Cumulative
feedback pulses
―
AL17
Servo status when alarm occurs
Servo motor speed
―
AL18
Servo status when alarm occurs Droop pulses
―
AL19
Servo status when alarm occurs Override
―
AL20
Servo status when alarm occurs Torque limit
voltage
―
AL21
Servo status when alarm occurs
Regenerative load ratio
―
AL22
Servo status when alarm occurs Effective
load ratio
―
AL23
Servo status when alarm occurs Peak load
ratio
―
AL24
Servo status when alarm occurs
Instantaneous torque
―
AL25
Servo status when alarm occurs Within one-
revolution position
―
AL26
Servo status when alarm occurs ABS counter
―
AL27
Servo status when alarm occurs
Load inertia moment ratio
―
AL28
Servo status when alarm occurs Bus voltage
―
AL200
Alarm number from Alarm History
most recent alarm
―
AL201
Alarm number from Alarm History
first alarm in past
―
AL202
Alarm number from Alarm History
second alarm in past
―
AL203
Alarm number from Alarm History
third alarm in past
―
AL204
Alarm number from Alarm History
fourth alarm in past
―
AL205
Alarm number from Alarm History
fifth alarm in past
―
AL210
Alarm occurrence time in alarm history
most recent alarm
―
AL211
Alarm occurrence time in alarm history
first alarm in past
―
AL212
Alarm occurrence time in alarm history
second alarm in past
―
AL213
Alarm occurrence time in alarm history
third alarm in past
―
AL214
Alarm occurrence time in alarm history
fourth alarm in past
―
AL215
Alarm occurrence time in alarm history
fifth alarm in past
―
AL230
Detailed alarm from Alarm History
most recent alarm
―
AL231
Detailed alarm from Alarm History
first alarm in past
―
AL232
Detailed alarm from Alarm History
second alarm in past
―
AL233
Detailed alarm from Alarm History
third alarm in past
―
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......