2 - 10
2. DEVICE RANGE THAT CAN BE SET
2.3 MELSEC-L
2.3
MELSEC-L
The device ranges that can be set when selecting
[MELSEC-L] as the controller type are as follows.
*1
Do not set a file register by GT Designer3 when executing
multiple programs with the file of the file register set at [Use
the same file name as the program] by the PLC parameter of
GX Developer.
Otherwise, read/write at GOT will be erroneous.
*2
Available for file register of block No. switched with the RSET
instruction.
*3
Available for file register of block No. of file name switched
with the QDRSET instruction.
*4
Only the intelligent function module on the station connected
to GOT can be specified.
Set within the address range of the buffer memory existing in
the target intelligent function module.
*5
Do not use local devices set in the MELSEC-L system.
Otherwise, normal monitoring is not performed. (The data
register (D) can be used for D32768 or later.)
*6
This cannot be monitored when in GOT multi-drop
connection.
*7
The device No. must be set in multiples of 16.
Device name
Setting range
Device No.
representation
B
it device
Input (X)
X0
to
X3FFF
Hexadecimal
Output (Y)
Y0
to
Y3FFF
Internal relay (M)
*5
M0
to
M61439
Decimal
Latch relay (L)
L0
to
L32767
Annunciator (F)
F0
to
F32767
Link relay (B)
B0
to
BEFFF
Hexadecimal
Timer
*5
Contact (TT)
TT0
to
TT32767
Decimal
Coil (TC)
TC0
to
TC32767
Counter
*5
Contact (CT)
CT0
to
CT32767
Coil (CC)
CC0
to
CC32767
Special relay (SM)
SM0
to
SM2047
Retentive
timer
*5
Contact (SS)
SS0
to
SS32767
Coil (SC)
SC0
to
SC32767
Step relay (S)
S0
to
S8191
Link special relay (SB)
SB0
to
SB7FFF
Hexadecimal
Word device bit
Specified bit of the
following word devices
(Except Timer, Counter,
Retentive timer, Index
register and Buffer
memory)
―
W
o
rd device
Data register (D)
*5
D0
to
D421887
Decimal
Special data register (SD)
SD0
to
SD2047
Link register (W)
W0
to
W66FFF
Hexadecimal
Timer (current value) (TN)
*5
TN0
to
TN32767
Decimal
Counter (current value)
(CN)
*5
CN0
to
CN32767
Retentive timer
(current value) (SN)
*5
SN0
to
SN32767
Link special register (SW)
SW0
to
SW7FFF
Hexadecimal
File register (R)
*1*2
R0
to
R32767
Decimal
Extension file register
(ZR)
*1*3
ZR0
to
ZR393215
Index register (Z)
Z0
to
Z19
Buffer memory
(Intelligent function module)
(G)
*4
G0
to
G65535
Ww
*6
Ww0
to
Ww1FFF
Hexadecimal
Wr
*6
Wr0
to
Wr1FFF
Bit device word
*7
Converting the above bit
devices into words
(Except Timer contact
and Counter contact)
―
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......