![Mitsubishi GOT2000 Series Connection Manual Download Page 490](http://html.mh-extra.com/html/mitsubishi/got2000-series/got2000-series_connection-manual_1808685490.webp)
15 - 26
15. SERVO AMPLIFIER CONNECTION
15.6 Device Range that Can Be Set
POINT
POINT
POINT
Precautions for SP, OM, TMB, TMI, TMO, and TMD
devices
(1) For bit devices
Only writing is possible.
[Alternate] of a bit switch cannot be used.
Use [Set], [Reset], and [Momentary] of a bit
switch.
(2) For word devices
Only writing is possible.
Numerical input cannot be used.
When writing, use [Word Set] of a data set switch.
The following shows correspondences between virtual
devices for servo amplifier and data of the servo
amplifier used with the GOT.
(a) Servo amplifier request
(b) Operation mode selection
(c) Instruction demand (for test operation)
(d) Basic parameter/expansion parameter
Device
name
Item
Symbol
SP0
Status display data clear
―
SP1
Current alarm clear
―
SP2
Alarm history clear
―
SP3
External input signal prohibited
―
SP4
External output signal prohibited
―
SP5
External input signal resumed
―
SP6
External output signal resumed
―
Device
name
Item
Symbol
OM0
Normal mode (not test operation mode)
―
OM1
JOG operation
―
OM2
Positioning operation
―
OM3
Motorless operation
―
OM4
Output signal (DO) forced output
―
Device name
Item
Symbol
TMB0
Clears the acceleration/
deceleration time constant
―
TMB1
Temporary stop command
―
Device name
Item
Symbol
*1
PRM0, PRM1000
Command system/
regenerative brake option
selection
*STY
PRM1, PRM1001
Feeding function selection
*FTY
PRM2, PRM1002
Function selection 1
*OP1
PRM3, PRM1003
Auto tuning
ATU
PRM4, PRM1004
Electronic gear numerator
*CMX
PRM5, PRM1005
Electronic gear denominator
*CDV
PRM6, PRM1006
In-position range
INP
PRM7, PRM1007
Position loop gain 1
PG1
PRM8, PRM1008
Home position return type
*ZTY
PRM9, PRM1009
Home position return speed
ZRF
PRM10, PRM1010
Creep speed
CRF
PRM11, PRM1011
Home position shift distance
ZST
PRM12, PRM1012
Rough match output range
CRP
PRM13, PRM1013
Jog speed
JOG
PRM14, PRM1014
S-pattern acceleration/
deceleration time constant
*STC
PRM15, PRM1015
Station number setting
*SNO
PRM16, PRM1016
Serial communication function
selection,
alarm history clear
*BPS
PRM17, PRM1017
Analog monitor output
MOD
PRM18, PRM1018
Status display selection
*DMD
PRM19, PRM1019
Parameter block
*BLK
PRM20, PRM1020
Function selection 2
*OP2
PRM21, PRM1021
For manufacturer setting
―
PRM22, PRM1022
Function selection 4
*OP4
PRM23, PRM1023
Serial communication time-out
selection
SIC
PRM24, PRM1024
Feed forward gain
FFC
PRM25, PRM1025
Override offset
VCO
PRM26, PRM1026
Torque limit offset
TLO
PRM27, PRM1027
Encoder output pulses
*ENR
PRM28, PRM1028
Internal torque limit 1
TL1
PRM29, PRM1029
Internal torque limit 2
TL2
PRM30, PRM1030
Backlash compensation
*BKC
PRM31,PRM1031
Analog monitor 1 offset
MO1
PRM32, PRM1032
Analog monitor 2 offset
MO2
PRM33, PRM1033
Electromagnetic brake
sequence output
MBR
PRM34, PRM1034
Ration of load inertia moment
to servo motor inertia moment
GD2
PRM35, PRM1035
Position control gain 2
PG2
PRM36, PRM1036
Speed control gain 1
VG1
PRM37, PRM1037
Position control gain 2
VG2
PRM38, PRM1038
Speed integral compensation
VIC
PRM39, PRM1039
Speed differential
compensation
VDC
PRM40 to PRM41,
PRM1040 to PRM1041
For manufacturer setting
―
PRM42, PRM1042
Home position return position
data
*ZPS
PRM43, PRM1043
Moving distance after
proximity dog
DCT
PRM44, PRM1044
Moving distance
after proximity dog
ZTM
PRM45, PRM1045
Stopper type home position
return torque limit value
ZTT
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......