9 - 22
9. MELSECNET/H CONNECTION (PLC TO PLC NETWORK), MELSECNET/10 CONNECTION (PLC TO
PLC NETWORK)
(1) Station number setting switch
: Necessary
: As necessary
: Not necessary
*1
Do not set the same station No. as that of the GOT.
(2) Mode setting switch
: Necessary
: As necessary
: Not necessary
POINT
POINT
POINT
When the switch setting has been changed
Turn the PLC CPU OFF then ON again, or reset the
PLC CPU.
Parameter setting (when connecting to
MELSEC-Q or QS series)
(1) [Network parameter] of GX Developer
(a) Network parameter
: Necessary
: As necessary
: Not necessary
*1
When using Q170MCPU, set it according to the system
configuration.
*2
Specify the same network No. as that of the GOT.
*3
Set it when the MELSECNET/H network module is used in
the redundant QnPRHCPU system.
Station number
setting switch
Description
Set value
Setting
necessity
at GOT
connection
Station number
setting
(Station No.1)
*1
1
Mode setting switch
Description
Set value
Setting
necessity
at GOT
connection
Mode setting
(Online: 10Mbps)
0 (fixed)
Item
Set value
Setting
necessity at
GOT
connection
Network type
MNET/10 mode
(Control station) (fixed)
Starting I/O No.
*1
0000
H
Network No.
*2
1
Total stations
2
Group No.
0 (fixed)
Mode
Online (fixed)
Network range assignment
Refer to (b)
Refresh parameters
(Use default value)
Interrupt settings
Control station return setting
Redundant settings
*3
Interlink transmission
parameters
Routing parameters
Refer to (c)
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......