14 - 46
14. INVERTER CONNECTION
14.6 Device Range that Can Be Set
(7) Special parameter
The numbers of the inverter’s virtual devices (SP) used
for the GOT correspond to instruction codes of the
inverter communication function.
For instruction details, and values to be read and
written, refer to the following,
Manual of the inverter used
*1
GOT cannot monitor SP109 to SP111 if the conditions below
are satisfied at the same time.
(Only FREQROL-E500/S500(E)/F500J/D700/F700PJ/E700
series)
• Pr37
0
• SP127 = 1
*2
Only reading is possible for SP111 to SP114.
These devices cannot be used for a write object (numerical
input etc.).
*3
Only writing is possible for SP124 and SP125.
These devices cannot be used for read object.
Inverter (FREQROL 800 series)
(Automatic connection)
*1
Only 16-bit (1-word) designation is possible.
*2
Only reading is possible.
*3
When the GOT is connected to the PU connector and the
operation mode is set to the PU operation mode, the multi-
speed operation (W3 to W7, SP121, SP122) cannot be used.
For using the multi-speed operation, follow either of the
operations as below.
• Connect the GOT to the RS-485 terminal and set the
operation mode to the NET operation mode (Computer
link operation mode), and then operate the inverter.
• Change the motor speed with the set frequency (SP109,
SP110), and then operate the inverter with the forward or
reverse rotation (WS1, WS2, SP121, SP122).
Device
name
Description
Instruction
code
Read
Write
SP108
Second parameter changing
6C
H
EC
H
SP109
*1
Set frequency (RAM)
6D
H
ED
H
SP110
*1
Set frequency (RAM, E
2
PROM)
6E
H
EE
H
SP111
*1*2
Output frequency
6F
H
-
SP112
*2
Output current
70
H
-
SP113
*2
Output voltage
71
H
-
SP114
*2
Special monitor
72
H
-
SP115
Special monitor selection No.
73
H
F3
H
SP116
Alarm definition all clear
-
F4
H
Latest alarm, second alarm in past
74
H
-
SP117
Third alarm in past, fourth alarm in past
75
H
-
SP118
Fifth alarm in past, sixth alarm in past
76
H
-
SP119
Seventh alarm in past, eights alarm in
past
77
H
-
SP121
Inverter status monitor (extended)
79
H
F9
H
Run command (extend)
SP122
Inverter status monitor
7A
H
-
Run command
-
FA
H
SP123
Communication mode
7B
H
FB
H
SP124
*3
All parameter clear
-
FC
H
SP125
*3
Inverter reset
-
FD
H
SP127
Link parameter extended setting
7F
H
FF
H
Device name
Setting range
Device
No.
represen
tation
Bit
d
e
v
ice
Inverter
status monitor
(RS)
*2
0-0 RS0
to
0-31 RS15
0-100 RS0
to
0-115 RS15
Decimal
Run command
(WS)
*3*4
0-0 WS0
to
0-31 WS15
0-100 WS0
to
0-115 WS15
Input (X)
0-0 X00
to
0-31 X7F
0-100 X00
to
0-115 X7F
Hexadec
imal
Output (Y)
0-0 Y00
to
0-31 Y7F
0-100 Y00
to
0-115 Y7F
Internal relay (M)
0-0 M0
to
0-31 M127
0-100 M0
to
0-115 M127
Decimal
Timer Coil (TC)
0-0 TC0
to
0-31 TC15
0-100 TC0
to
0-115 TC15
Timer Contact (TT)
0-0 TT0
to
0-31 TT15
0-100 TT0
to
0-115 TT15
Counter Coil (CC)
0-0 CC0
to
0-31 CC15
0-100 CC0
to
0-115 CC15
Counter Contact
(CT)
0-0 CT0
to
0-31 CT15
0-100 CT0
to
0-115 CT15
Retentive timer
Coil (SC)
0-0 SC0
to
0-31 SC15
0-100 SC0
to
0-115 SC15
Retentive timer
Contact (SS)
0-0 SS0
to
0-31 SS15
0-100 SS0
to
0-115 SS15
Special relay
(SM)
*5
0-0 SM0
to
0-31 SM2047
0-100 SM0
to
0-115 SM2047
W
o
rd device
Alarm definition (A)
*1*2
0-0 A0
to
0-31 A7
0-100 A0
to
0-115 A7
Decimal
Parameter (Pr)
*1
0-0 Pr0
to
0-31 Pr1500
0-100 Pr0
to
0-115 Pr1500
Special parameter
(SP)
*1*3
0-0 SP108
to
0-31 SP127
0-100 SP108 to
0-115 SP127
Timer current value
(TN)
0-0 TN0
to
0-31 TN15
0-100 TN0
to
0-115 TN15
Counter current
value (CN)
0-0 CN0
to
0-31 CN15
0-100 CN0
to
0-115 CN15
Retentive timer
current value (SN)
0-0 SN0
to
0-31 SN15
0-100 SN0
to
0-115 SN15
Data register (D)
0-0 D0
to
0-31 D255
0-100 D0
to
0-115 D255
Special data
register (SD)
0-0 SD0
to
0-31 SD2047
0-100 SD0
to
0-115 SD2047
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......