15. SERVO AMPLIFIER CONNECTION
15.6 Device Range that Can Be Set
15 - 39
SER
VO AMPLIFIER CONNECTION
15
(9) MELSERVO-J4-*A, -JE-*A
*1
Use 1 to 80 of PA, PB, PC, PD, PE, and PF when the GOT
writes data to RAM of the servo amplifier.
Use 1001 to 1080 of PA, PB, PC, PD, PE, and PF when the
GOT write data to E
2
PROM of the servo amplifier.
*2
The GOT cannot read or write data from/to consecutive
devices.
*3
Only reading is possible.
*4
Only reading is possible for DI0 to DI1.
POINT
POINT
POINT
Precautions for SP, OM, TMB, TMI, TMO, and TMD
devices
(1) For bit devices
Only writing is possible.
[Alternate] of a bit switch cannot be used.
Use [Set], [Reset], and [Momentary] of a bit
switch.
(2) For word devices
Only writing is possible.
Numerical input cannot be used.
When writing, use [Word Set] of a data set switch.
The following shows correspondences between virtual
devices for servo amplifier and data of the servo
amplifier used with the GOT.
(a) Servo amplifier request
(b) Operation mode selection
*1
MELSERVO-JE is equivalent to MELSERVO-J4.
However, they have differences in the parameter function.
For using the MELSERVO-JE series, refer to the following.
MELSERVO-JE Series Servo Amplifier Instruction
Manual
(c) Instruction demand (for test operation)
Device name
*2
Setting range
Device
No.
represen
tation
Bit
device
Servo amplifier request (SP) SP0
to
SP6
Decimal
Operation mode selection
(OM)
OM0 to
OM4
Instruction demand
(for test operation) (TMB)
TMB1 to
TMB6
Wo
rd
d
e
v
ic
e
Basic setting parameter
(PA)
*1
PA1 to
PA32
PA1001 to PA1032
Gain
filter parameter
(PB)
*1
PB1 to
PB64
PB1001 to
PB1064
Extension setting
parameter (PC)
*1
PC1 to
PC80
PC1001 to PC1080
I/O setting parameter
(PD)
*1
PD1 to
PD48
PD1001 to PD1048
Extension setting 2
parameter (PE)
*1
PE1 to
PE64
PE1001 to PE1064
Extension setting 3
parameter (PF)
*1
PF1 to
PF48
PF1001 to PF1048
Status display (ST)
*3
ST0 to
ST41
Alarm (AL)
*3
AL0 to
AL1
AL11 to
AL25
AL200 to AL205
AL210 to AL215
AL230 to AL235
Alarm (ALM)
*3
ALM0 to
ALM1
ALM11 to
ALM52
ALM200 to ALM215
ALM220 to ALM235
ALM240 to ALM255
External input (DI)
*4
DI0 to
DI2
External output (DO)
*3
DO0 to
DO1
Input signal for test operation
(for test operation) (TM0)
TMI0
Forced output of signal pin
(for test operation) (TMO)
TMO0
Set data
(for test operation) (TMD)
TMD0 to
TMD1
TMD3
Device
name
Item
Symbol
SP0
Status display data clear
―
SP1
Current alarm clear
―
SP2
Alarm history clear
―
SP3
External input signal prohibited
―
SP4
External output signal prohibited
―
SP5
External input signal resumed
―
SP6
External output signal resumed
―
Device
name
Item
Symbol
OM0
Normal mode (not test operation mode)
―
OM1
JOG operation
―
OM2
Positioning operation
―
OM3
*1
Motorless operation
―
OM4
Output signal (DO) forced output
―
Device
name
Item
Symbol
TMB1
Temporary stop command
―
TMB2
Test operation (positioning operation) start
command
―
TMB3
Forward rotation direction
―
TMB4
Reverse rotation direction
―
TMB5
Restart for remaining distance
―
TMB6
Remaining distance clear
―
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......