15 - 22
15. SERVO AMPLIFIER CONNECTION
15.6 Device Range that Can Be Set
(e) Status display
(f)
Alarm
(g) Input signal for test operation (for test operation)
(h) Forced output of signal pin (for test operation)
(i)
Set data (for test operation)
Device name
Item
Symbol
ST0
Cumulative feedback pulses
―
ST1
Servo motor speed
―
ST2
Droop pulses
―
ST3
Cumulative command pulses
―
ST4
Command pulse frequency
―
ST5
Effective load ratio
―
ST6
Peak load ratio
―
ST7
Instantaneous torque
―
ST8
Within one-revolution position
―
ST9
ABS counter
―
ST10
Load inertia moment ratio
―
Device
name
Item
Symbol
AL0
Current alarm number
―
AL11
Servo status when alarm occurs cumulative
feedback pulses
―
AL12
Servo status when alarm occurs
servo motor speed
―
AL13
Servo status when alarm occurs droop
pulses
―
AL14
Servo status when alarm occurs cumulative
command pulses
―
AL15
Servo status when alarm occurs command
pulse frequency
―
AL16
Servo status when alarm occurs effective
load ratio
―
AL17
Servo status when alarm occurs peak load
ratio
―
AL18
Servo status when alarm occurs
instantaneous torque
―
AL19
Servo status when alarm occurs within one-
revolution position
―
AL20
Servo status when alarm occurs ABS
counter
―
AL21
Servo status when alarm occurs
load inertia moment ratio
―
AL200
Alarm number from alarm history
most recent alarm
―
AL201
Alarm number from alarm history
first alarm in past
―
AL202
Alarm number from alarm history
second alarm in past
―
AL203
Alarm number from alarm history
third alarm in past
―
AL204
Alarm number from alarm history
fourth alarm in past
―
AL205
Alarm number from alarm history
fifth alarm in past
―
AL210
Alarm occurrence time in alarm history
most recent alarm
―
AL211
Alarm occurrence time in alarm history
first alarm in past
―
AL212
Alarm occurrence time in alarm history
second alarm in past
―
AL213
Alarm occurrence time in alarm history
third alarm in past
―
AL214
Alarm occurrence time in alarm history
fourth alarm in past
―
AL215
Alarm occurrence time in alarm history
fifth alarm in past
―
AL230
Detailed alarm from alarm history
most recent alarm
―
AL231
Detailed alarm from alarm history
first alarm in past
―
AL232
Detailed alarm from alarm history
second alarm in past
―
AL233
Detailed alarm from alarm history
third alarm in past
―
AL234
Detailed alarm from alarm history
fourth alarm in past
―
AL235
Detailed alarm from alarm history
fifth alarm in past
―
Device
name
Item
Symbol
TMI0
Input signal for test operation
―
Device
name
Item
Symbol
TMO0
Forced output of signal pin
―
Device
name
Item
Symbol
TMD0
Writes the speed (test mode)
―
TMD1
Writes the acceleration/deceleration time
constant (test mode)
―
TMD2
Writes the moving distance in pulses (test
mode)
―
Device
name
Item
Symbol
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......