5. ETHERNET CONNECTION
5.2 System Configuration
5 - 9
5
ETHERN
ET C
O
NN
ECTION
When connecting to MELSEC-FX
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
A cross cable is available for connecting the GOT to the Ethernet module.
*2
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*3
For the system configuration of the Ethernet module, refer to the following manuals.
For FX Ethernet Interface Module User’s Manual
*4
Select one of the following [Controller Type] in [Ethernet] of GT Designer3.
• Ethernet module (FX Series): FX
For [Ethernet] of GT Designer3, refer to the following.
*5
When using an Ethernet module with the FX
3UC
series, FX
2NC
-CNV-IF or FX
3UC
-1PS-5V is required.
*6
When using an Ethernet module with the FX
3U
series, FX
3U
-CNV-BD, FX
3U
-422-BD, or FX
3U
-232-BD is required.
*7
FX
3U
-ENET-ADP occupies one extension communication adapter CH (Max. 2 CHs) of the FX
3U(C)
or FX
3G(C)
and one extension
communication adapter CH (Max. 1 CH) of the FX
3S
. One CPU allows the connection of only one FX
3U
-ENET-ADP.
Ethernet
module
GOT
Connection cable
PLC CPU
Ethernet (FX), Gateway
Communication driver
PLC
Connection cable
*1
Maximum
segment
length
*2
GOT
Number of
connectable
equipment
Model name
Ethernet module
*3*4
Communication
type
Cable model
Option device
Model
MELSEC-FX
(FX
3U
, FX
3G
)
FX
3U
-ENET-L
Ethernet
• 100BASE-TX
Shielded twisted pair
cable (STP) or unshielded
twisted pair cable (UTP)
of category 5 or higher
• 10BASE-T
Shielded twisted pair
cable (STP) or unshielded
twisted pair cable (UTP)
of category 3 or higher
100m
- (Built into GOT)
2 GOTs
MELSEC-FX
(FX
3UC
, FX
3GC
)
FX
3UC
-1PS-5V,
FX
2NC
-CNV-IF
+
FX
3U
-ENET-L
*5
Ethernet
MELSEC-FX
(FX
3U
)
FX
3U
-CNV-BD,
FX
3U
-422-BD,
FX
3U
-232-BD,
+
FX
3U
-ENET-ADP
*6*7
Ethernet
• 100BASE-TX
Shielded twisted pair
cable (STP) or unshielded
twisted pair cable (UTP)
of category 5 or higher
• 10BASE-T
Shielded twisted pair
cable (STP) or unshielded
twisted pair cable (UTP)
of category 3 or higher
100m
- (Built into GOT)
4 GOTs
MELSEC-FX
(FX
3UC
)
FX
3U
-ENET-ADP
Ethernet
MELSEC-FX
(FX
3G
)
FX
3G
-CNV-ADP,
+
FX
3U
-ENET-ADP
*7
Ethernet
MELSEC-FX
(FX
3GC
)
FX
3U
-ENET-ADP
*7
Ethernet
MELSEC-FX
(FX
3S
)
FX
3S
-CNV-ADP
+
FX
3U
-ENET-ADP
*7
Ethernet
Summary of Contents for GOT2000 Series
Page 2: ......
Page 62: ...1 38 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring ...
Page 64: ......
Page 80: ...2 16 2 DEVICE RANGE THAT CAN BE SET 2 6 MELSEC WS ...
Page 246: ...7 26 7 COMPUTER LINK CONNECTION 7 6 Precautions ...
Page 252: ...8 6 8 BUS CONNECTION 8 1 Connectable Model List ...
Page 256: ...8 10 8 BUS CONNECTION 8 2 System Configuration ...
Page 288: ...8 42 8 BUS CONNECTION 8 4 Precautions ...
Page 324: ...9 36 9 MELSECNET H CONNECTION PLC TO PLC NETWORK MELSECNET 10 CONNECTION PLC TO PLC NETWORK ...
Page 416: ......
Page 510: ...15 46 15 SERVO AMPLIFIER CONNECTION 15 7 Precautions ...
Page 518: ...16 8 16 ROBOT CONTROLLER CONNECTION 16 6 Precautions ...
Page 540: ...17 22 17 CNC CONNECTION 17 7 Precautions ...
Page 541: ...MULTIPLE GOT CONNECTIONS 18 GOT MULTI DROP CONNECTION 18 1 ...
Page 542: ......
Page 567: ...MULTI CHANNEL FUNCTION 19 MULTI CHANNEL FUNCTION 19 1 ...
Page 568: ......
Page 599: ...FA TRANSPARENT FUNCTION 20 FA TRANSPARENT FUNCTION 20 1 ...
Page 600: ......
Page 668: ...20 68 20 FA TRANSPARENT FUNCTION 20 7 Precautions ...
Page 670: ...REVISIONS 2 ...
Page 673: ......