13 - 48
13. POSITIONING MODE
(2) Servo motor rotation direction
Parameter No. PA14 setting
Servo motor rotation direction
Manual pulse generator: forward rotation Manual pulse generator: reverse rotation
0
CCW rotation
CW rotation
1
CW rotation
CCW rotation
CW
CCW
Forward
rotation
(3) Manual pulse generator multiplication
Use parameter No.PA05 to set the multiplication ratio of the servo motor rotation to the manual pulse
generator rotation.
Parameter No. PA05 setting
Multiplication ratio of servo motor rotation to
manual pulse generator rotation
Travel distance
0
1 time
1[μm]
1
10 times
10[μm]
2
100 times
100[μm]
(4) Operation
Turn the manual pulse generator to rotate the servo motor. For the rotation direction of servo motor, refer to
(2) in this section.