4 - 47
4. PARAMETERS
No. Symbol
Name and function
Initial
value
Setting
range
Unit
Control mode
Position Internal
speed
Internal
torque
PD03 *DI1-1 Input signal device selection 1L (CN1-3)
Any input signal can be assigned to the CN1-3 pin.
Note that the setting digits and the signal that can be assigned vary
depending on the control mode.
Position control mode
Internal speed control mode
Select the
input device
of the CN1-
3 pin.
The devices that can be assigned in each control mode are indicated
by symbols in the following table. If any other device is set, it is invalid.
0303h Refer to
the name
and
function
field.
Setting
Control modes (Note 1)
P
S
T
CP/CL
00
01
For manufacturer setting (Note 2)
02
SON
SON
SON
SON
03
RES
RES
RES
RES
04
PC
PC
PC
05
(Note 4) EM1
EM1
EM1
EM1
06
CR
07
ST1
RS2
ST1
08
ST2
RS1
ST2
09
TL1
TL1
TL1
0A
LSP
LSP
LSP
0B
LSN
LSN
LSN
0C
For manufacturer setting (Note 2)
0D
SP1
SP1
0E
SP2
SP2
0F
SP3
SP3
10
LOP
LOP
LOP
11
CDP
CDP
CDP
12 to 1F
For manufacturer setting (Note 2)
20
MD0
21 to 23
For manufacturer
setting (Note 2)
24
TSTP
25
For manufacturer
setting (Note 2)
26
DOG
27
PI1 (Note 3)
28 to 2B
For manufacturer
setting (Note 2)
2C
DI0
2D
DI1
2E
DI2
2F to 3F
For manufacturer
setting (Note 2)
Note 1. P: Position control mode
S: Internal speed control mode
T: Internal torque control mode
CP: Positioning mode (Point table method)
CL: Positioning mode (Program method)
2. For manufacturer setting. Never set this value.
3. It is valid in the positioning mode (Program method)
only.
4. When operating temporarily without using EM1 such
as at startup, etc., set the EM1 to automatic ON in
parameter No.PD01.
Summary of Contents for MELSERVO-JN Series
Page 31: ... 22 MEMO ...
Page 49: ...2 6 2 INSTALLATION MEMO ...
Page 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Page 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Page 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Page 351: ...12 48 12 SERVO MOTOR MEMO ...
Page 445: ...13 94 13 POSITIONING MODE MEMO ...