3 - 14
3. SIGNALS AND WIRING
(2) CN1 signal assignment
The signal assignment of connector changes with the control mode as indicated below;
For the pins which are given parameter No. in the related parameter column, their signals can be changed
using those parameters.
Pin No.
(Note 1)
I/O
(Note 2) I/O signals in control modes
Related
parameter No.
P
P/S
S
S/T
T
T/P
1
DICOM
DICOM
DICOM
DICOM
DICOM
DICOM
2
OPC
OPC/-
-/OPC
3
I
RES
RES
RES
RES
RES
RES
PD03 PD04
4
I
SON
SON
SON
SON
SON
SON
PD05 PD06
5
I
CR
CR/SP1
SP1
SP1/SP1
SP1
SP1/CR
PD07 PD08
6
I
LSP
LSP/ST1
ST1
ST1/RS2
RS2
RS2/LSP
PD09 PD10
7
I
LSN
LSN/ST2
ST2
ST2/RS1
RS1
RS1/LSN
PD11 PD12
8
I
EM1
EM1
EM1
EM1
EM1
EM1
PD13 PD14
9
O
ALM
ALM
ALM
ALM
ALM
ALM
PD15
10
O
INP
INP/SA
SA
SA/-
-/INP
PD16
11
O
RD
RD
RD
RD
RD
RD
PD17
12
O
MBR
MBR
MBR
MBR
MBR
MBR
PD18
13
DOCOM
DOCOM
DOCOM
DOCOM
DOCOM
DOCOM
14
LG
LG
LG
LG
LG
LG
15
O
LA
LA
LA
LA
LA
LA
16
O
LAR
LAR
LAR
LAR
LAR
LAR
17
O
LB
LB
LB
LB
LB
LB
18
O
LBR
LBR
LBR
LBR
LBR
LBR
19
O
LZ
LZ
LZ
LZ
LZ
LZ
20
O
LZR
LZR
LZR
LZR
LZR
LZR
21
O
OP
OP
OP
OP
OP
OP
22
I
PG
PG/-
-/PG
23
I
PP
PP/-
-/PP
PD02
24
I
NG
NG/-
-/NG
25
I
NP
NP/-
-/NP
PD02
26
Note 1. I: Input signal, O: Output signal
2. P: Position control mode, S: Internal speed control mode, T: Internal torque control mode,
P/S: Position/internal speed control change mode, S/T: Internal speed/internal torque control change mode,
T/P: Internal torque/position control change mode
Summary of Contents for MELSERVO-JN Series
Page 31: ... 22 MEMO ...
Page 49: ...2 6 2 INSTALLATION MEMO ...
Page 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Page 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Page 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Page 351: ...12 48 12 SERVO MOTOR MEMO ...
Page 445: ...13 94 13 POSITIONING MODE MEMO ...