APPENDIX
App. - 5
Extension setting parameters (PC
)
I/O setting parameters (PD
)
No. Symbol
Name
No. Symbol
Name
PC01
This parameter is not used.
PD01 *DIA1 Input signal automatic ON selection 1
PC02
PD02 *DI0 Input signal device selection 0 (CN1-23,
CN1-25)
PC03 STC S-pattern acceleration/deceleration time
constant
PD03 *DI1-1 Input signal device selection 1L (CN1-3)
PC04
to
PC08
This parameter is not used.
PD04 *DI1-2 Input signal device selection 1H (CN1-3)
PD05 *DI2-1 Input signal device selection 2L (CN1-4)
PD06 *DI2-2 Input signal device selection 2H (CN1-4)
PC09 MBR Electromagnetic brake sequence output
PD07 *DI3-1 Input signal device selection 3L (CN1-5)
PC10 ZSP Zero speed
PD08 *DI3-2 Input signal device selection 3H (CN1-5)
PC11 *BPS Alarm history clear
PD09 *DI4-1 Input signal device selection 4L (CN1-6)
PC12
This parameter is not used.
PD10 *DI4-2 Input signal device selection 4H (CN1-6)
PC13 *ENRS Encoder output pulses selection
PD11 *DI5-1 Input signal device selection 5L (CN1-7)
PC14 TL2 Internal torque limit 2
PD12 *DI5-2 Input signal device selection 5H (CN1-7)
PC15 ERZL Error excessive alarm detection level
PD13 *DI6-1 Input signal device selection 6L (CN1-8)
PC16
For manufacturer setting
PD14 *DI6-2 Input signal device selection 6H (CN1-8)
PC17 *OSL Overspeed alarm detection level
PD15 *DO1 Output signal device selection 1 (CN1-9)
PC18
For manufacturer setting
PD16 *DO2 Output signal device selection 2 (CN1-10)
PC19
PD17 *DO3 Output signal device selection 3 (CN1-11)
PC20
PD18 *DO4 Output signal device selection 4 (CN1-12)
PC21
PD19 *DIF Input filter setting
PC22 *COP1 Function selection C-1
PD20 *DOP1 Function selection D-1
PC23
This parameter is not used.
PD21
For manufacturer setting
PC24 *COP3 Function selection C-3
PD22 *DOP3 Function selection D-3
PC25 *COP4 Function selection C-4
PD23
For manufacturer setting
PC26 ALDT Detailed setting of overload tough drive
PD24 *DOP5 Function selection D-5
PC27 OSCL Detailed setting of vibration tough drive
PD25
For manufacturer setting
PC28 CVAT Detailed setting of instantaneous power
failure tough drive
PD26
PC29 *COP5 Function selection C-5
PC30
to
PC34
This parameter is not used.
PC35
to
PC43
For manufacturer setting
PC44 RECT Drive recorder alarm designation
PC45
to
PC64
For manufacturer setting
Summary of Contents for MELSERVO-JN Series
Page 31: ... 22 MEMO ...
Page 49: ...2 6 2 INSTALLATION MEMO ...
Page 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Page 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Page 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Page 351: ...12 48 12 SERVO MOTOR MEMO ...
Page 445: ...13 94 13 POSITIONING MODE MEMO ...