8 - 20
8. TROUBLESHOOTING
Alarm No.: A.51
Name: Overload 2
Description
Machine collision or the like caused continuous flow of the maximum output current for a few seconds.
Detailed
display
Detailed
Name
Cause
Checking method
Result
Action
51.1
Overload
thermal 3
error during
operation
1) Power cables breakage
Check the power
cables.
An error is found.
Repair the power cables.
No error.
Check 2).
2) Incorrect connection with
the servo motor
Check the wiring of U,
V and W.
An error is found.
Wire correctly.
No error.
Check 3).
3) Incorrect connection of the
encoder cable
Check if the encoder
cable is connected
correctly.
An error is found.
Correct the connection.
No error.
Check 4).
4) The work collided against
the structural part.
Check if the work
collided against the
structural part.
Collided.
Check the operation
pattern.
Did not collide.
Check 5).
5) Torque is saturated.
Check the torque
during the operation.
Torque is saturated. Check the operation
pattern.
Torque is not
saturated.
Check 6).
6) Servo amplifier fault
Check if the alarm
occurs after replacing
the servo amplifier.
Alarm does not
occur.
Replace the servo
amplifier.
Alarm occurs.
Check 7).
7) Encoder faulty.
Check if the alarm
occurs after replacing
the servo motor.
Alarm does not
occur.
Replace the servo motor.
51.2
Overload
thermal 3
error at a
stop
1) Power cables breakage
Execute the checking methods mentioned in the alarm display "51.1".
2) Incorrect connection with
the servo motor
3) Incorrect connection of the
encoder cable
4) The work collided against
the structural part.
5) Torque is saturated.
6) Servo amplifier fault
7) Encoder faulty.
Summary of Contents for MELSERVO-JN Series
Page 31: ... 22 MEMO ...
Page 49: ...2 6 2 INSTALLATION MEMO ...
Page 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Page 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Page 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Page 351: ...12 48 12 SERVO MOTOR MEMO ...
Page 445: ...13 94 13 POSITIONING MODE MEMO ...