APPENDIX
App. - 18
App. 5.6 Transportation and storage
CAUTION
Transport the products correctly according to their mass.
Stacking in excess of the limited number of product packages is not allowed.
Install the product in a load-bearing place of servo amplifier and servo motor in
accordance with the instruction manual.
Do not put excessive load on the machine.
Do not hold the lead of the built-in regenerative resistor, the cables, or the
connectors when carrying the servo amplifier. Otherwise, it may drop.
When you keep or use the product, please fulfill the following environment.
Item
Environment
Ambient
temperature
Operation
[°C]
0 to 55 Class 3K3 (IEC/EN 60721-3-3)
Transportation (Note) [°C]
-20 to 65 Class 2K4 (IEC/EN 60721-3-2)
Storage (Note)
[°C]
-20 to 65 Class 1K4 (IEC/EN 60721-3-1)
Ambient
humidity
Operation, transportation,
storage
5 %RH to 90 %RH
Vibration
resistance
Test condition
10 Hz to 57 Hz with constant amplitude of 0.075 mm
57 Hz to 150 Hz with constant acceleration of 9.8 m/s
2
to IEC/EN 61800-5-1
(Test Fc of IEC 60068-2-6)
Operation
5.9 m/s
2
Transportation (Note)
Class 2M3 (IEC/EN 60721-3-2)
Storage
Class 1M2 (IEC/EN 60721-3-2)
Pollution degree
2
IP rating
IP20 (IEC/EN 60529)
Open type (UL 50)
Altitude
Operation, storage
1000 m or less
Transportation
10000 m or less
Note. In regular transport packaging
Summary of Contents for MELSERVO-JN Series
Page 31: ... 22 MEMO ...
Page 49: ...2 6 2 INSTALLATION MEMO ...
Page 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Page 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Page 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Page 351: ...12 48 12 SERVO MOTOR MEMO ...
Page 445: ...13 94 13 POSITIONING MODE MEMO ...