4 - 25
4. PARAMETERS
No. Symbol
Name and function
Initial
value
Setting
range
Unit
Control mode
Position
Internal
speed
Internal
torque
PB13 NH1 Machine resonance suppression filter 1
Set the notch frequency of the machine resonance suppression filter 1.
Executing one-touch tuning automatically changes this parameter.
When parameter No. PB01 is set to " 0", the setting of this
parameter is ignored.
4500
30
to
4500
Hz
PB14 NHQ1 Notch shape selection 1
Used to select the machine resonance suppression filter 1.
Notch depth selection
Setting Depth
Gain
0
40dB
Deep
1
14dB
2
8dB
3
4dB
Shallow
to
Notch width selection
Width
0
2
Standard
1
3
2
4
3
5
Wide
to
0
Setting
Executing one-touch tuning automatically changes this parameter.
When parameter No. PB01 is set to " 0", the setting of this
parameter is ignored.
000h Refer to
name
and
function
column.
PB15 NH2 Machine resonance suppression filter 2
Set the notch frequency of the machine resonance suppression filter
2.
Set parameter No. PB16 (notch shape selection 2) to " 1" to
make this parameter valid.
Executing one-touch tuning automatically changes this parameter.
4500
30
to
4500
Hz
PB16 NHQ2 Notch shape selection 2
Select the shape of the machine resonance suppression filter 2.
Notch depth selection
Depth
Gain
0
Deep
1
14dB
2
8dB
3
4dB
Shallow
to
Notch width selection
Width
0
2
Standard
1
3
2
4
3
5
Wide
to
Machine resonance suppression filter 2 selection
0: Invalid
1: Valid
Setting
Setting
40dB
Executing one-touch tuning automatically changes this parameter.
000h Refer to
name
and
function
column.
Summary of Contents for MELSERVO-JN Series
Page 31: ... 22 MEMO ...
Page 49: ...2 6 2 INSTALLATION MEMO ...
Page 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Page 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Page 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Page 351: ...12 48 12 SERVO MOTOR MEMO ...
Page 445: ...13 94 13 POSITIONING MODE MEMO ...