13. POSITIONING MODE
13.6.7 Home position ignorance (Servo-on position as home position)
The position where servo is switched on is defined as a home position.
(1) Devices and parameters
Set the input devices and parameters as follows.
Item
Device/Parameter used
Description
Manual home position return
mode selection
Automatic/manual selection (MD0) Turn MD0 ON.
Point table No./Program No.
selection 1 to 3 (DI0 to DI2)
Point table method: Select the home position return
mode by turning OFF DI0, DI1 and
DI2.
Program method: Select a program that has the home
position return "ZRT" command.
Home position ignorance
Parameter No. PE03
4: Home position ignorance is selected.
Home position return position
data
Parameter No. PE08
Set the current position at home position return
completion.
(2) Timing chart
ON
OFF
Servo-on (SON)
ON
OFF
Ready (RD)
ON
OFF
Automatic/manual
selection (MD0)
ON
OFF
Travel completion
(MEND)
ON
OFF
Rough match (CPO)
ON
OFF
Home position return
completion (ZP)
Servo motor
speed
Home position address
parameter No. PE08
0r/min
The set value in parameter No. PE08 (home position return position data) is applied as position address at
the time of the home position return being completed.
Summary of Contents for MELSERVO-JN Series
Page 31: ... 22 MEMO ...
Page 49: ...2 6 2 INSTALLATION MEMO ...
Page 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Page 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Page 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Page 351: ...12 48 12 SERVO MOTOR MEMO ...
Page 445: ...13 94 13 POSITIONING MODE MEMO ...