13 - 86
13. POSITIONING MODE
13.8 Point table setting method
This section provides the method for setting the point table by using MR Configurator.
POINT
Positioning mode is supported by MR Configurator with software version C4
or later.
The value of the parameter No. PE02 set on the parameter setting screen is
not interlocked with the STM (feed length multiplication) value on the point
table list screen. Set the STM (feed length multiplication) value to the same
as set in the parameter No. PE02 on the point table list screen.
Click "Positioning-data" on the menu bar, and click "Point table" on the menu.
When the above choices are made, the following window appears.
h)
g)
f)
c)
a)
b)
d)
e)
(1) Writing point table data ( a) )
Click the point table data changed, and click the "Write" button to write the new point table data to the
servo amplifier.
(2) Verifying point table data ( b) )
Click the "Verify" button to verify all data being displayed and the data of the servo amplifier.
(3) Batch-reading point table data ( c) )
Click the "Read All" button to read and display all point table data from the servo amplifier.
(4) Batch-writing point table data ( d) )
Click the "Write All" button to write all point table data to the servo amplifier.
Summary of Contents for MELSERVO-JN Series
Page 31: ... 22 MEMO ...
Page 49: ...2 6 2 INSTALLATION MEMO ...
Page 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Page 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Page 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Page 351: ...12 48 12 SERVO MOTOR MEMO ...
Page 445: ...13 94 13 POSITIONING MODE MEMO ...