3 - 45
3. SIGNALS AND WIRING
(3) Alarm occurrence
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
Electromagnetic
brake interlock (MBR)
(10ms)
Electromagnetic brake
operation delay time
Trouble (ALM)
No (ON)
Yes (OFF)
Base circuit (Note 1)
ON
Servo motor speed
OFF
(Note 2) ON
OFF
Note 1. Electromagnetic brake sequence output (parameter No. PC09) is invalid.
2. ON: Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.
(4) Both main and control circuit power supplies off
Main circuit
Control circuit
(10ms)
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
10 to 60ms
(Note 1)
Electromagnetic brake
operation delay time
Electromagnetic
brake interlock
(MBR)
ON
Base circuit
Servo motor speed
Trouble (ALM)
power
supply
OFF
ON
OFF
ON
OFF
No (ON)
Yes (OFF)
(Note 2)
Note 1. Changes with the operating status.
2. ON: Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.