![Mitsubishi Electric MELSERVO-JN Series Instruction Manual Download Page 300](http://html.mh-extra.com/html/mitsubishi-electric/melservo-jn-series/melservo-jn-series_instruction-manual_1811804300.webp)
11 - 43
11. OPTIONS AND PERIPHERAL EQUIPMENT
(3) Outline drawing
HF3010A-UN
[Unit: mm]
M4
IN
32
2
85
2
110
4
3-M4
65 4
Approx.41
4-5.5 7
258 4
273 2
288 4
300 5
3-M4
11.13 Surge protector (recommended)
To avoid damages caused by surges (such as lightning and sparking) applied on AC power line, connecting
the following surge protectors to the main circuit power (L
1
L
2
) is recommended.
(1) Specifications
Surge protector
model
Circuit voltage
50/60Hz
Maximum
permissible circuit
voltage
Clamp voltage
Surge immunity
8/20μs
Surge compression
1.2/50μs
Static
capacity
Operating
temperature
RAV-781BYZ-2
3AC 250V
300V
783V±10%
2500A
20kV
75pF
20 to 70
RAV-781BXZ-4
3AC 250V
300V
1700V±10%
2500A
2kV
75pF
20 to 70