12 - 28
12. SERVO MOTOR
12.6.2 Specifications
(1) Specifications list (When combined with an MR-JN- A series servo amplifier.)
Servo motor
Item
HF-KP series (Low inertia, small capacity)
053G1/G5/G7
13G1/G5/G7
23G1/G5/G7
43G1/G5/G7
Applicable servo
amplifier
MR-JN- A
10
20
40
MR-JN- A1
10
20
Continuous
running duty
(Note 1)
Rated output
[kW]
0.05
0.1
0.2
0.4
Rated torque
(Note 8)
[N m]
0.16
0.32
0.64
1.3
[oz in]
22.7
45.3
90.6
184
Rated speed (Note 1, 3)
[r/min]
3000
Maximum speed (Note 3)
[r/min]
4500
Instantaneous permissible speed
[r/min]
4500
Maximum torque (Note 8)
[N m]
0.48
0.95
1.9
3.8
[oz in]
68.0
135
269
538
Power rate at continuous rated torque
(Note 8)
[kW/s]
4.87
11.5
16.9
38.6
Inertia moment
J [×10
-4
kg m
2
]
Refer to sections 6.8.3 to 6.8.8 in the Servo Motor INSTRUCTION MANUAL
(Vol.2).
WK
2
[oz in
2
]
Recommended load to motor inertia moment
ratio (Note 2)
Refer to section 12.6.4
Power supply capacity
Refer to section 10.2.
Rated current
[A]
0.9
0.8
1.4
2.7
Maximum current
[A]
2.7
2.4
4.2
8.1
Speed/position encoder
Incremental 18-bit encoder
(Resolution per servo motor 1 rotation: 262144pulses/rev)
Accessory
Insulation class
Class B
Structure
Totally-enclosed, self-cooled (IP rating: IP44 (Note 4))
Environmental
conditions
(Note 5)
Ambient
temperature
In operation
0 to +40 (32 to 104 ) (non-freezing)
In storage
-15 to +70 (5 to 158 ) (non-freezing)
Ambient
humidity
In operation
10%RH to 80%RH (non-condensing)
In storage
10%RH to 90%RH (non-condensing)
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m
Vibration resistance (Note 6)
X, Y : 49m/s
2
Vibration rank (Note 7)
V-10
Permissible load for the shaft
Refer to section 12.6.4.
Mass
[kg] ([lb])
Refer to sections 6.8.3 to 6.8.8 in the Servo Motor INSTRUCTION MANUAL
(Vol.2).
Note 1. When the power supply voltage drops, the output and the rated speed cannot be guaranteed.
2. If the load to motor inertia moment ratio exceeds the indicated value, please contact your local sales office.
3. The above values are in the reduction gear input shaft.
4. Except for the shaft-through portion.
5. In the environment where the servo motor is exposed to oil mist, oil and/or water, a standard specification servo motor may not
be usable. Contact your local sales office.
Summary of Contents for MELSERVO-JN Series
Page 31: ... 22 MEMO ...
Page 49: ...2 6 2 INSTALLATION MEMO ...
Page 181: ...5 30 5 DISPLAY AND OPERATION SECTIONS MEMO ...
Page 199: ...6 18 6 GENERAL GAIN ADJUSTMENT MEMO ...
Page 303: ...11 46 11 OPTIONS AND PERIPHERAL EQUIPMENT MEMO ...
Page 351: ...12 48 12 SERVO MOTOR MEMO ...
Page 445: ...13 94 13 POSITIONING MODE MEMO ...