5-11
There is an error in the data trans-
mitted from CAD.
Make sure the CAD data. (P.4-5)
DISPLAY OF ERROR MESSAGE
INVALID PARAMETER
O V E R R U N E R R O R
SAME PEN NOTHING 0.
*
SAME PEN NOTHING #
*
P L E A S E C L O S E C O V E R
P-EDGE SENSOR ERROR
R E D O F R O M S T A R T .
I L L E G A L P O I N T S E T .
PM-BUFFER OVER-FLOW
Error Message
Probable Cause
Corrective Measure
Conductive noise entraps in the
communication line.
The interface cable specified by MI-
MAKI is not used.
There is an error in setting of com-
munication conditions.
After supplying lead, there is no ap-
plicable mechanical pencil. (Under
auto mode)
After supplying lead, a mechanical
pencil was attached on the magazine
of different No. (Under manual
mode)
The front cover does not open.
Use a shorter interface cable.
Use the interface cable specified by
MIMAKI.
Execute auto interprete of communica-
tion conditions, and set proper commu-
nication conditions. (P.3-25)
Set the same lead diameter mechani-
cal pencil on the magazine.
Set the mechanical pencil of which pen
No. is the same as that of the mechani-
cal pencil which have been used.
Close the front cover.
Synchro-roller and platen cover
have been soiled on the surface.
1 or 2 exceeds 45
°
and above.
Polygonal plotting (hatching) can
not be achieved. (Short of memory)
Clean up the surfaces of synchro-roller
and platen.(P.xii)
Set wirhin 45
°
. (P.3-16)
Separately Set on the coordinates re-
spectively. (P.3-16)
Change the setting established on CAD.
Then, Ensure the buffer space with the
GM command.
Either 2 points and above among
Points 1, 2 and 3 are set at the same
point.
DISPLAY OF ERROR MESSAGE
Troubles Enabling Plotter to Continue Operation
When the following error messages are displayed, find the error message from the following table, then remove
the probable cause in accordance with the corrective measure. It is unnecessary to turn the power 0FF and ON
again.
If the error message would be still displayed after removing the cause, send facsimile transmission of the "IN-
QUIRY SHEET" (P.6-18) to the MIMAKI distributor listed in the table at the end of this instruction manual upon
entering the required information.
Summary of Contents for cg-100AP
Page 16: ...xiv ...
Page 70: ...1 54 ...
Page 108: ...2 38 ...
Page 145: ...CHAPTER 4 SELF DIAGNOSIS FUNCTION 4 9 DEMONSTRATION PATTERN 1 2 Demonstration Pattern 1 ...
Page 146: ...4 10 Demonstration Pattern 2 ...
Page 173: ...CHAPTER 6 APPENDIX 6 13 Table of 82 special character codes supported ...
Page 179: ...D200310MAC 2 00 09061999 ...
Page 180: ... MIMAKI ENGINEERING CO LTD 1999 6 Printed in japan ...