Calibrating the Swath Compressor Sensor
This topic only applies to machines equipped with a swath compressor. To calibrate the swath compressor sensor, follow
these steps:
1011772
C###
E###
WINDROWER SETUP?
NO/YES
A
B
Figure 4.96: CDM Programming Buttons
1.
Turn the ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (B) on the cab display
module (CDM) to enter programming mode.
•
WINDROWER SETUP? is displayed on the upper line.
3.
Press SELECT (B) until CALIBRATE SENSORS? is displayed on
the upper line.
•
NO/YES is displayed on the lower line.
1030061
SWATH SENSOR CAL
SWATH UP TO START
C###
E###
B
A
Figure 4.97: Swath Compressor Sensor Calibration
4.
Press right arrow (A) to select YES. Press SELECT (B).
•
TO CALIBRATE SELECT is displayed in upper line.
5.
Press right arrow (A) to scroll through the choices until
SWATH COMPR HT is displayed on the lower line. Press
SELECT (B).
•
SWATH SENSOR CAL is displayed on the upper line.
•
SWATH UP TO START is displayed on the lower line.
1022623
A
B
Figure 4.98: Swath Compressor Controls
A - Lower Swath Compressor
B - Raise Swath Compressor
6.
Press and hold button (B) to raise the swath compressor.
•
CALIBRATING SWATH is displayed on the upper line.
•
FORM UP and flashing HOLD is displayed on the lower
line until the system has completed reading signal with
swath compressor fully raised.
•
SWATH FORM UP DONE (with buzzer) is displayed on
the lower line when complete.