215104
121
Revision A
4.3.16
Setting the Engine Intermediate Speed Control (ISC) RPM
The Engine Intermediate Speed Control (ISC) feature provides three selectable engine speeds (1900, 2050, or 2200 rpm) for
reduced load conditions. The default setting is 2200 rpm or the last selected rpm.
NOTE:
The engine
MUST
be running to perform this procedure.
1011786
CXXX
EXXX
WINDROWER SETUP?
NO/YES
A
B
C
Figure 4.51: CDM Programming Buttons
1.
Start the engine.
2.
Press PROGRAM (A) and SELECT (C) on the cab display
module (CDM) to enter programming mode.
•
WINDROWER SETUP? is displayed on the upper line.
•
NO/YES is displayed on the lower line.
3.
Press right arrow (B) to select YES. Press SELECT (C).
•
SET KNIFE SPEED? is displayed on the upper line.
1026913
CXXX
EXXX
SET ENGINE ISC RPM?
NO/YES
B
A
Figure 4.52: Engine ISC RPM
4.
Press SELECT (B) until SET ENGINE ISC RPM? is displayed on
the upper line.
•
NO/YES is displayed on the lower line.
5.
Press right arrow (A) to select YES. Press SELECT (B).
•
PRESS HAZARD TO SET is displayed on the upper line.
•
ISC RPM #### is displayed on the lower line.
Table 4.1 ISC Settings
ISC and rpm
Off
8
1
2
High Idle
2050
1900
NOTE:
The previously selected ISC rpm will be flashing.
8.
Off is always used when the header is not engaged.