215104
85
Revision A
1007437
A
B
Figure 3.117: View from beneath Tank
3.
Remove drain plug (A) from under tank (B) and drain.
4.
Add some DEF to tank (B) to flush out remaining
contaminants.
5.
Drain the DEF that was used to clean the tank.
6.
Reinstall drain plug (A) in tank (B).
1018098
A
Figure 3.118: DEF Tank
IMPORTANT:
Before refilling the DEF tank, read the following instructions
from decal (A) located on the tank cover:
•
Before storing the machine for longer than six months,
drain the DEF tank to prevent degradation of fluid.
•
Before storing the machine in temperatures below 0°C
(32°F), ensure the level of fluid in the DEF tank is 75 %
or lower.
Take the following precautions when handling DEF to prevent contamination:
•
Avoid using funnels and containers that have been used with fuels or lubricants.
•
Use only distilled water to rinse the components that store or deliver DEF; tap water can contaminate DEF.
•
If distilled water is not available, use clean tap water, then rinse components with DEF.
1007400
A
Figure 3.119: DEF Tank
7.
Clean around filler cap (A).
8.
Turn cap (A) counterclockwise until loose and
remove the cap.
9.
Fill the tank with an approved DEF. Refer to the windrower
operator
’
s manual for specifications.
10. Replace filler cap (A) and turn it clockwise until it is tight.
11. Close the maintenance platform.