XGB Analog edition manual
15 - 44
Max. MV: 4000
- Max. MV is set as 4000. If MV is 4000, XBF-DV04A outputs 10V.
Min. MV: 0
- Min. MV is set as 0. If MV is 0, XBF-DV04A outputs 0V.
PWM junction, PWM output cycle
- It is not necessary to set it because the example does not use PWM output.
Hysteresis setting: 10
(2) A/D input module parameter setting
(a) If double-clicking Parameter
– I/O parameter, it opens up the setting window as illustrated
in figure 15.19.
[ Figure 15.19 I/O parameter setting window ]
(b) If selecting A/D module for a slot in A/D input module, it opens up the setting window as
illustrated in Figure 15.20.
[ Figure 15.20 A/D input mode setting window ]
(c) Check A/D Module operation parameter and click OK. The example is set as follows.
RUN CH: CH0 RUN
- The example receives the water level sensor input as CH0.
Input scope: 0 ~ 10V
- Set XBF-AD04A input scope as 0 ~ 10V so that it should be identical with the output
Summary of Contents for XGB Series
Page 70: ...XGB Analog edition manual 2 36 Program in case of IEC type ...
Page 72: ...XGB Analog edition manual 2 38 ...
Page 73: ...Chapter 2 Analog Input Module XBF AD04A 2 39 Program in case of IEC type ...
Page 491: ...XGB Analog edition manual 4 Click Yes 5 As shown below the variables are registered 13 30 ...
Page 581: ...XGB Analog edition manual 15 32 In case of IEC type APM_WRT funcion block is used ...
Page 614: ...Appendix 3 Appendix 3 4 7 Dimension of XBF AD08A Unit mm 8 Dimension of XBO AD02A Unit mm ...
Page 615: ...Appendix 3 Appendix 3 5 9 Dimension of XBO DA02A Unit mm 10 Dimension of XBO AH02A Unit mm ...
Page 616: ...Appendix 3 Appendix 3 6 11 Dimension of XBO RD01A Unit mm 12 Dimension of XBO TC02A Unit mm ...