Chapter 13 Analog Input Module (XBF-AD04C)
(3) DC 1 ~ 5V Input range
Digital
output range
Analog input voltage (V)
0.952
1
2
3
4
5
5.047
Unsigned Value
(-192 ~ 16,191)
-192
0
4,000
8,000
12,000
16,000
16,191
Signed Value
(-8,192 ~ 8,191)
-8,192
-8,000
-4,000
0
4,000
8,000
8,191
Precise Value
(952 ~ 5,047)
952
1,000
2,000
3,000
4,000
5,000
5,047
Percentile Value
(-120 ~ 10,119)
-120
0
2,500
5,000
7,500
10,000
10,119
(4) DC 0 ~ 5V Input range
Digital
output range
Analog input voltage (V)
-0.06
0
1.25
2.5
3.75
5
5.059
Unsigned Value
(-192 ~ 16,191)
-192
0
4,000
8,000
12,000
16,000
16,191
Signed Value
(-8,192 ~ 8,191)
-8,192
-8,000
-4,000
0
4,000
8,000
8,191
Precise Value
(-60 ~ 5,059)
-60
0
1,250
2,500
3,750
5,000
5,059
Percentile Value
(-120 ~ 10,119)
-120
0
2,500
5,000
7,500
10,000
10,119
(5) DC 0 ~ 10V Input range
Digital
output range
Analog input voltage (V)
-0.12
0
2.5
5
7.5
10
10.119
Unsigned Value
(-192 ~ 16,191)
-192
0
4,000
8,000
12,000
16,000
16,191
Signed Value
(-8,192 ~ 8,191)
-8,192
-8,000
-4,000
0
4,000
8,000
8,191
Precise Value
(-120 ~ 10,119)
-120
0
2,500
5,000
7,500
10,000
10,119
Percentile Value
(-120 ~ 10,119)
-120
0
2,500
5,000
7,500
10,000
10,119
(6) DC -10 ~ 10V Input range
Digital
output range
Analog input voltage (V)
-10.24
-10
-5
0
5
10
10.239
Unsigned Value
(-192 ~ 16,191)
-192
0
4,000
8,000
12,000
16,000
16,191
Signed Value
(-8,192 ~ 8,191)
-8,192
-8,000
-4,000
0
4,000
8,000
8,191
Precise Value
(-10,240 ~ 10,239)
-10,240
-10,000
-5,000
0
5,000
10,000
10,239
Percentile Value
(-120 ~ 10,119)
-120
0
2,500
5,000
7,500
10,000
10,119
13 - 7
Summary of Contents for XGB Series
Page 70: ...XGB Analog edition manual 2 36 Program in case of IEC type ...
Page 72: ...XGB Analog edition manual 2 38 ...
Page 73: ...Chapter 2 Analog Input Module XBF AD04A 2 39 Program in case of IEC type ...
Page 491: ...XGB Analog edition manual 4 Click Yes 5 As shown below the variables are registered 13 30 ...
Page 581: ...XGB Analog edition manual 15 32 In case of IEC type APM_WRT funcion block is used ...
Page 614: ...Appendix 3 Appendix 3 4 7 Dimension of XBF AD08A Unit mm 8 Dimension of XBO AD02A Unit mm ...
Page 615: ...Appendix 3 Appendix 3 5 9 Dimension of XBO DA02A Unit mm 10 Dimension of XBO AH02A Unit mm ...
Page 616: ...Appendix 3 Appendix 3 6 11 Dimension of XBO RD01A Unit mm 12 Dimension of XBO TC02A Unit mm ...