XGB Analog edition manual
(4) Count average value setting area (address 3)
(a) Set count average value with 0 or value of 2~6400
(b) If you set the count average value as 0, corresponding channel will not perform averaging
process and output sampled analog input value
(c) If you set 1 or more than 64001, 0 (Disable averaging) will be set forcibly.
But, U0X.01.8 (Setup error flag) will be ON.
(d) When using PUT instruction, address is as follows
bit15
bit14
bit13
bit12
bit11
bit10
bit9
bit8
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Input CH0 count average value (0 or 2 ~ 64000 [times])
Address
3
(e) This area is same as setting in “Count-Avr” of I/O parameter
(5) Channel output state setting area (address 8)
(a) Set the output state setting with the following code
Bit (Hex)
Channel output state
0000 (0)
Former value
0001 (1)
Min value
0010 (2)
Middle value
0011 (3)
Max value
10 - 38
Summary of Contents for XGB Series
Page 70: ...XGB Analog edition manual 2 36 Program in case of IEC type ...
Page 72: ...XGB Analog edition manual 2 38 ...
Page 73: ...Chapter 2 Analog Input Module XBF AD04A 2 39 Program in case of IEC type ...
Page 491: ...XGB Analog edition manual 4 Click Yes 5 As shown below the variables are registered 13 30 ...
Page 581: ...XGB Analog edition manual 15 32 In case of IEC type APM_WRT funcion block is used ...
Page 614: ...Appendix 3 Appendix 3 4 7 Dimension of XBF AD08A Unit mm 8 Dimension of XBO AD02A Unit mm ...
Page 615: ...Appendix 3 Appendix 3 5 9 Dimension of XBO DA02A Unit mm 10 Dimension of XBO AH02A Unit mm ...
Page 616: ...Appendix 3 Appendix 3 6 11 Dimension of XBO RD01A Unit mm 12 Dimension of XBO TC02A Unit mm ...