Chapter 6 Instruction Details
XBC E-Type Main Unit
6-190
Ver. 1
(2) -32,768~32,767(BIN 16-bit) of integer is available for S2.
2) Program Example
(1) If Input Signal P00000 is changed from Off to ON status, it saves the result of GWAND operation 5-word
data from P1000~P1004 with 5-word data from P1100~P1104 in 5-word of P1200~1204 respectively.
GWAND P1000 P1100 P1200 5
P00000
S1+1
1 0 1 1 0 1 0 1 1 0 1 0 1 1 0 0
S1
b15
b8
b0
b7
1 0 1 1 1 0 1 0 1 0 1 1 1 0 1 0
S1+2
0 1 0 1 0 1 1 0 0 0 1 1 1 0 0 1
S1+(N-2) 1 1 1 1 0 1 1 1 1 0 1 1 1 0 0 0
S1+(N-1) 1 1 1 1 0 1 0 1 1 0 0 1 0 1 1 1
n
AND
D+1
1 0 1 1 0 1 0 1 1 0 0 0 1 0 0 0
D
b15
b8
b0
b7
1 0 1 1 0 0 1 0 1 0 0 1 1 0 0 0
D+2
0 0 0 1 0 1 1 0 0 0 0 1 1 0 0 1
D+(N-2)
1 0 1 1 0 1 1 1 1 0 0 1 1 0 0 0
D+(N-1)
1 0 1 1 0 1 0 1 1 0 0 1 0 0 0 1
n
S2
b15
b8
b0
b7
1 0 1 1 0 1 1 1 1 0 0 1 1 0 0 1
Summary of Contents for XBC-DN10E