Chapter 6 Instruction and Flag List
XBC E-Type Main Unit
6-225
Ver. 1
contact point (Instruction) OFF to make specified D1 device’s value 0.
(6) In specified D2 device, 2-point (SORT)/4-point (DSORT) is used by system when the instruction is executed.
User shall not change 2-point (SORT)/4-point (DSORT) in specified D2 device.
(7) If N has been changed while being sorted, it sorts with the number of sorted data after change.
2) Program Example
SORT
P1000
P1100
P1200
P1300
P1400
P00000
Caution
(1) Be careful of using indirect designation (#) or index ([Z]) because the SORT/DSORT instruction has internal
processing parts without contact point ON.
For example, an error occurs without contact point ON if you use M100[Z10] for one of the SORT instruction
operands and if Z10’s value exceeds 1947 that can be outside the M area.
Summary of Contents for XBC-DN10E
Page 1: ......
Page 10: ...Table of Contents Table of Contents 6 10 10 CLEAR ALL PLC 29...